Diabetes Care · 2024 · 17 citations · 8 references
MedicineEndocrinologyHealth InformaticsDiabetologyHealth Data AnalyticsHealth Technology AssessmentBlood Glucose MonitoringContinuous Glucose MonitoringDiabetes ManagementDiabetes MellitusGlycemic ControlGlycemic MonitoringContinuous Glucose Monitoring Guided TherapyGlucose MonitoringGlycemic Control TargetsGlycemic TargetsInsulin Delivery DevicesInsulin ManagementSevere Hypoglycemia Management
OBJECTIVE: We captured continuous glucose monitoring (CGM) metrics from a large online survey of adults with type 1 diabetes to determine how glycemic outcomes varied by insulin delivery form. RESEARCH DESIGN AND METHODS: Adults with type 1 diabetes from the T1D Exchange Registry/online communities completed the survey and contributed retrospective CGM data for up to 1 year. Self-reported glycemic outcomes and CGM measures were described overall and by insulin delivery method. RESULTS: The 926 participants completed the survey and provided CGM data. Mean ± SD age was 41.9 ± 15.7 years, and 50.8% reported using automated insulin delivery (AID). While AID users spent more time in range, 27.9% did not achieve time in range targets, 15.5% reported severe hypoglycemic events (SHEs), and 16.0% had CGM-detected level 2 hypoglycemic events. CONCLUSIONS: Despite use of diabetes technologies, many individuals are unable to achieve glycemic targets and experience severe hypoglycemia, highlighting the need for novel treatments.
8
William H. Polonsky, Danielle Hessler, Katrina J. Ruedy et al. · Diabetes Care · 2017 · 326 citations
Jennifer L. Sherr, Lori M. Laffel, Jingwen Liu et al. · Diabetes Care · 2024 · 89 citations · Full text