Performance of a hard x-ray undulator at CHESS (invited)

D. H. Bilderback, B. W. Batterman, M. J. Bedzyk, K. D. Finkelstein, C. Henderson, A. Merlini, W. Schildkamp, Qun‐Dong Shen, J. White, E. Blum,

Review of Scientific Instruments · 1989 · 29 citations · 2 references

Concepts

Abstract

A 3.3-cm period Nd-Fe-B hybrid undulator has been designed and successfully operated in the Cornell Electron Storage Ring (CESR). This 2-m-long, 123-pole insertion device is a prototype of one of the undulators planned for the Advanced Photon Source. In dedicated operation, the undulator produced the expected brightness at 5.437 GeV with the fundamental x-ray energy ranging from 4.3 to 7.9 keV corresponding to a change in gap from 1.5 to 2.8 cm.

References

2