Building and Environment · 2024 · 18 citations · 45 references
ArchitectureArchitectural EngineeringBuilding ScienceDesign OptimizationEnergy ManagementThermal ComfortBuilding Energy ModelingBuilding Energy PerformanceBuilding Energy SystemsEnergy Efficiency In HeatingEnergy-efficient DesignHvac System DesignBuilding Energy Consumption AnalysisBuilding Energy Performance SimulationHvac Energy OptimizationIndoor Environmental Quality AnalysisIndoor Environmental Quality OptimizationIndoor Thermal Comfort OptimizationMulti-objective Optimization Of EnergyPrediction Models
The complex correlation between energy consumption, Indoor Environmental Quality (IEQ) and occupancy is significant for residential buildings but often overlooked in design and operation phases. While it is easier to set standards for energy and IEQ individually, accounting for the influence of occupants on both simultaneously presents a significant challenge. This complexity affects the accuracy of prediction models and the effectiveness of multi-objective optimisation. This research proposes a low-computational methodology based on a metamodel approach tailored for rapid prediction and optimisation of heating energy consumption (kWh), thermal discomfort (hours), and elevated CO 2 levels (hours) under the influence of occupancy. The framework evaluates occupancy's impact on the Pareto optimal front generated through metamodel-based multi-objective optimisation. The optimisation process reduced computation time by 80% compared to traditional models, with over 99% accuracy. The study highlights that variables like occupancy density, metabolic rate, and window operations significantly influence heating consumption, thermal discomfort, and CO 2 levels. Higher occupancy and metabolic rates increase internal heat gains, reducing heating demand but risking overheating without adequate ventilation. Window operations balance air quality and thermal comfort; however, prolonged ventilation may cause heat loss in colder conditions. Including occupancy-related variables ensures predicted results and optimised parameters are resilient and within WHO and CIBSE TM59 limits, while aligning heating consumption with energy-efficient standards.
45
Joseph G. Allen, Piers MacNaughton, Usha Satish et al. · Environmental Health Perspectives · 2015 · 935 citations · Full text
Shaoqing Gou, Vahid M. Nik, Jean‐Louis Scartezzini et al. · Energy and Buildings · 2017 · 310 citations · Full text
Architecture, Architectural Engineering, Building Science +17