Circulation · 2024 · 69 citations · 26 references
MedicineCardiologyCardiothoracic SurgeryClinical CardiologyElectrophysiologyCardiac PacingImplantable Cardioverter-defibrillator CareIntracardiac ElectrophysiologyImplantable Cardioverter DefibrillatorsIntracardiac PacingKaplan-meier Confidence IntervalsLead PlacementLong-term Cardiac Follow-upPacing ThresholdsPivotal Study DesignProcedure-related Complications
BACKGROUND: Substernal lead placement of the extravascular implantable cardioverter defibrillator (EV ICD) permits both defibrillation at thresholds similar to those seen with transvenous implantable cardioverter defibrillators and effective anti-tachycardia pacing (ATP) while avoiding the vasculature and associated complications. The global Pivotal study has shown the EV ICD system to be safe and effective through 6 months, but long-term experience has yet to be published. Our aim was to report the performance and safety of the EV ICD system throughout the study. METHODS: The EV ICD Pivotal study was a prospective, global, single-arm, premarket clinical study. Individuals with a Class I or IIa indication for a single-chamber implantable cardioverter defibrillator per guidelines were enrolled. Freedom from major system- or procedure-related complications and appropriate and inappropriate therapy rates were assessed through 3 years with the Kaplan-Meier method. ATP success was calculated from simple proportions. RESULTS: An implantation was attempted in 316 patients (25.3% female; 53.8±13.1 years of age; 81.6% primary prevention; left ventricular ejection fraction, 38.9±15.4%). Of 299 patients with a successful implantation, 24 experienced 82 spontaneous arrhythmic episodes that were appropriately treated with ATP only (38, 46.3%), shock only (34, 41.5%), or both (10, 12.2%) for a Kaplan-Meier–estimated rate of first any appropriate therapy of 9.2% at 3 years. ATP was successful in 77.1% (37/48) of episodes, and ATP use significantly increased from discharge to last follow-up visit ( P <0.0001). Shock therapy was successful in 100% (27/27) of discrete, spontaneous ventricular arrhythmias. The inappropriate shock rates at 1 and 3 years were 9.8% and 17.5%, respectively, with P-wave oversensing the predominant cause. No major intraprocedural complications were reported, and the estimated freedom from system- or procedure-related major complications was 91.9% at 1 year and 89.0% at 3 years. The most common major complications were lead dislodgement (10 events; n=9 patients, 2.8%), postoperative wound or device pocket infection (n=8, 2.5%), and device inappropriate shock delivery (n=4, 1.3%). Twenty-four system revisions were performed as a result of major complications related to the EV ICD system or procedure. CONCLUSIONS: From implantation to study completion, the EV ICD Pivotal study demonstrated that a single integrated system with an extravascular lead placed in the substernal space maintains high ATP success, effective defibrillation, and a consistent safety profile. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04060680.
26
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Gust H. Bardy, Kerry L. Lee, Daniel B. Mark et al. · New England Journal of Medicine · 2005 · 6.5K citations · Full text
An Entirely Subcutaneous Implantable Cardioverter–Defibrillator
Gust H. Bardy, Warren Smith, Margaret Hood et al. · New England Journal of Medicine · 2010 · 774 citations · Full text
Mark S. Wathen, Paul DeGroot, Michael O. Sweeney et al. · Circulation · 2004 · 769 citations
Safety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter Defibrillator
Raul Weiss, Bradley P. Knight, Michael R. Gold et al. · Circulation · 2013 · 553 citations