EBioMedicine · 2024 · 14 citations · 18 references
Public HealthImmunologyInfectious DiseasesDiagnostic MicrobiologyMolecular DiagnosticsTuberculosis ControlMycobacterial DiagnosticsPulmonary TuberculosisTuberculosis CareTuberculosis DiagnosisTuberculosis Diagnostic TestingTuberculosis EpidemiologyCapture AntibodiesComparative Diagnostic AccuracyDiagnostic Accuracy StudiesDiagnostic SensitivityDiagnostic Testing AccuracyPulmonary Tuberculosis DiagnosisTuberculosis BiomarkersTuberculosis Diagnostics
Background Development of a non-sputum test using readily-obtainable biospecimens remains a global priority for tuberculosis (TB) control. We quantified lipoarabinomannan (LAM) concentrations, a pathogen biomarker for Mycobacterium tuberculosis , in urine, plasma and serum for real-world diagnostic accuracy of pulmonary TB among people living with and without HIV. Methods We conducted a prospective diagnostic study among adults with TB symptoms in South Africa. We measured LAM concentrations in time-matched urine, plasma and serum with an electrochemiluminescence immunoassay using two capture antibodies (FIND 28 and S4–20). From the completed cohort, we randomly selected 210 participants (2 cases: 1 control) based on sensitivity estimates, and we compared diagnostic accuracy of LAM measurements against the microbiological reference standard. Findings Urine and blood specimens from 210 of 684 adults enrolled were tested for LAM. Among 138 TB-positive adults (41% female), median urine LAM was 137 pg/mL and 52 pg/mL by FIND 28 and S4–20, respectively. Average LAM concentrations were highest in HIV-positive participants with CD4+ T cells <200 cells/mm 3 . Urine LAM by S4–20 achieved diagnostic sensitivity of 62% (95% CI: 53%–70%) and specificity of 99% (95% CI: 96%–100%). Plasma and serum LAM by FIND 28 showed similar sensitivity (70%, 95% CI: 62%–78%) and comparable specificities (90%, 95% CI: 82%–97%; 94%, 95% CI: 88%–99%). Diagnostic sensitivity of urine LAM by S4–20 was higher among participants without HIV (41%, 95% CI: 24%–61%) compared to HIV-positive participants with CD4 ≥200 cells/mm 3 (20%, 95% CI: 8%–39%). Interpretation Detection of LAM was achievable in non-sputum specimens for pulmonary TB, but additional analyte concentration or signal amplification may be required to achieve diagnostic accuracy targets. Funding Bill and Melinda Gates Foundation.
18
Jonny Peter, Lynn S. Zijenah, Duncan Chanda et al. · The Lancet · 2016 · 265 citations
Public Health, Infectious Disease Control, Clinical Medicine +10
Ankur Gupta‐Wright, Elizabeth L. Corbett, Joep J. van Oosterhout et al. · The Lancet · 2018 · 208 citations · Full text
Public Health, Community Health, Infectious Disease Control +17
Jorge R Ledesma, Jianing Ma, Avina Vongpradith et al. · The Lancet Infectious Diseases · 2021 · 169 citations · Full text
Stephen D Lawn, Andrew D. Kerkhoff, Rosie Burton et al. · BMC Medicine · 2017 · 136 citations · Full text
George B. Sigal, Abraham Pinter, Todd L. Lowary et al. · Journal of Clinical Microbiology · 2018 · 122 citations · Full text