Physical Review Applied · 2024 · 10 citations · 41 references
Natural SciencesMaterials EngineeringMaterials ScienceCrystal StructureMagnetic MaterialsSensorsCrystal DirectionsMagnetic Properties Of SolidsMagnetic SensorsCrystal AxesDefect CentersDiamond Nitrogen-vacancy CentersMagnetometersSingle-crystal CrystallographyVector Magnetometry
In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in harsh environments. Moreover, the orientation of defect centers along four crystal axes forms an intrinsic coordinate system, enabling vector magnetometry within a single diamond crystal. While most vector magnetometers rely on a known bias magnetic field for full recovery of three-dimensional (3D) field information, employing external 3D Helmholtz coils or permanent magnets results in bulky, laboratory-bound setups, impeding miniaturization of the device. Here, a novel approach is presented that utilizes a fiber-integrated microscale coil at the fiber tip to generate a localized uniaxial magnetic field. The same fiber-tip coil is used in parallel for spin control by combining dc and microwave signals in a bias tee. To implement vector magnetometry using a uniaxial bias field, the orientation of the diamond crystal is preselected and then fully characterized by rotating a static magnetic field in three planes of rotation. The measurement of vector magnetic fields in the full solid angle is demonstrated with a shot-noise-limited sensitivity of <a:math xmlns:a="http://www.w3.org/1998/Math/MathML" display="inline" overflow="scroll"> <a:mn>19.4</a:mn> <a:mspace width="0.2em"/> <a:msup> <a:mtext>nT/Hz</a:mtext> <a:mrow> <a:mn>1</a:mn> <a:mo>/</a:mo> <a:mn>2</a:mn> </a:mrow> </a:msup> </a:math> and microscale spatial resolution while achieving a fiber sensor head cross section of less than <e:math xmlns:e="http://www.w3.org/1998/Math/MathML" display="inline" overflow="scroll"> <e:mn>1</e:mn> <e:mspace width="0.2em"/> <e:msup> <e:mtext>mm</e:mtext> <e:mn>2</e:mn> </e:msup> </e:math> . Published by the American Physical Society 2024
41
A note on two problems in connexion with graphs
E. Dijkstra · Numerische Mathematik · 1959 · 23.8K citations
Nanometre-scale thermometry in a living cell
Georg Kucsko, Peter C. Maurer, Norman Y. Yao et al. · Nature · 2013 · 2K citations · Full text
Electric-field sensing using single diamond spins
Florian Dolde, Helmut Fedder, Marcus W. Doherty et al. · Nature Physics · 2011 · 1.3K citations · Full text
Sensitivity optimization for NV-diamond magnetometry