EngineeringArchitectural EngineeringBuilding ScienceBuilding StructuresHeat TransferPassive DesignBuilding Cooling SystemsBuilding Energy SystemsBuilding Thermal PerformanceHeat Transfer In BuildingsThermal PerformanceThermal SimulationBuilding Envelope Thermal PropertiesBuilding Thermal DesignCompact Building DesignEmissivityEnergy-efficient BuildingsRadiative CoolingRadiative Cooling EffectsThermal Performance Modeling
With the gradually warming climate, the global cooling demand for buildings is rapidly increasing. Radiative cooling (RC) has been an attractive electricity-free approach to reducing the energy consumption of buildings. Current RC strategies focus on roofs; however, limited attention has been paid to vertical walls. Here, we report a zigzag-based structural design with asymmetric emissivity to realize optimal RC walls. Such asymmetry leads to a daily average temperature drop of 2.3°C compared to conventional walls coated with RC materials. When the ground is at ∼56°C, the temperature drop reaches 3.1°C, corresponding to a relative cooling power of 67 W m −2 compared to the control wall. Moreover, the energy impact of this zigzag wall in diverse climate conditions is analyzed based on building-scale simulations. Current limitations and future improvement directions are also discussed. This zigzag RC wall provides a new passive solution to energy-efficient buildings.
31
Passive radiative cooling below ambient air temperature under direct sunlight
Aaswath P. Raman, Marc Abou Anoma, Linxiao Zhu et al. · Nature · 2014 · 3.4K citations
A radiative cooling structural material
Tian Li, Yao Zhai, Shuaiming He et al. · Science · 2019 · 1.6K citations · Full text