European Radiology · 2024 · 21 citations · 30 references
MedicineCardiologyRadiologyCardiothoracic RadiologyDiagnostic ImagingDiagnostic RadiologyCardiac ImagingCardiovascular ImagingComputed TomographyCoronary AngiographyCoronary Artery ImagingMedical ImagingCardiac Computed TomographyComputed Tomography AngiographyCoronary Ct AngiographyExtracellular Volume ImagingIterative Image ReconstructionIterative ReconstructionPhoton-counting Coronary Computed TomographyPhoton-counting Detectors
Abstract Objectives To assess the accuracy of a synthetic hematocrit derived from virtual non-contrast (VNC) and virtual non-iodine images (VNI) for myocardial extracellular volume (ECV) computation with photon-counting detector computed tomography (PCD-CT). Materials and methods Consecutive patients undergoing PCD-CT including a coronary CT angiography (CCTA) and a late enhancement (LE) scan and having a blood hematocrit were retrospectively included. In the first 75 patients ( derivation cohort ), CCTA and LE scans were reconstructed as VNI at 60, 70, and 80 keV and as VNC with quantum iterative reconstruction (QIR) strengths 2, 3, and 4. Blood pool attenuation (BP mean ) was correlated to blood hematocrit. In the next 50 patients ( validation cohort ), synthetic hematocrit was calculated using BP mean . Myocardial ECV was computed using the synthetic hematocrit and compared with the ECV using the blood hematocrit as a reference. Results In the derivation cohort (49 men, mean age 79 ± 8 years), a correlation between BP mean and blood hematocrit ranged from poor for VNI of CCTA at 80 keV, QIR2 ( R 2 = 0.12) to moderate for VNI of LE at 60 keV, QIR4; 70 keV, QIR3 and 4; and VNC of LE, QIR3 and 4 (all, R 2 = 0.58). In the validation cohort (29 men, age 75 ± 14 years), synthetic hematocrit was calculated from VNC of the LE scan, QIR3. Median ECV was 26.9% (interquartile range (IQR), 25.5%, 28.8%) using the blood hematocrit and 26.8% (IQR, 25.4%, 29.7%) using synthetic hematocrit (VNC, QIR3; mean difference, −0.2%; limits of agreement, −2.4%, 2.0%; p = 0.33). Conclusion Synthetic hematocrit calculated from VNC images enables an accurate computation of myocardial ECV with PCD-CT. Clinical relevance statement Virtual non-contrast images from cardiac late enhancement scans with photon-counting detector CT allow the calculation of a synthetic hematocrit, which enables accurate computation of myocardial extracellular volume. Key Points Blood hematocrit is mandatory for conventional myocardial extracellular volume computation. Synthetic hematocrit can be calculated from virtual non-iodine and non-contrast photon-counting detector CT images. Synthetic hematocrit from virtual non-contrast images enables computation of the myocardial extracellular volume.
30
Extracellular Myocardial Volume in Patients With Aortic Stenosis
Russell J. Everett, Thomas A. Treibel, Miho Fukui et al. · Journal of the American College of Cardiology · 2020 · 238 citations · Full text
Medicine, Cardiology, Radiology +17
Ultra-High-Resolution Coronary CT Angiography With Photon-Counting Detector CT
Victor Mergen, Thomas Sartoretti, Matthias Baer‐Beck et al. · Investigative Radiology · 2022 · 194 citations · Full text
Medicine, Cardiology, Radiology +17
Automatic Measurement of the Myocardial Interstitium
Thomas A. Treibel, Marianna Fontana, Viviana Maestrini et al. · JACC. Cardiovascular imaging · 2016 · 164 citations
Medicine, Cardiology, Physiology +6