Circulation Arrhythmia and Electrophysiology · 2024 · 17 citations · 20 references
MedicineBioengineeringBiomedical EngineeringElectrophysiologyInterventional CardiologyTissue EngineeringAblation TherapyCatheter AblationAblation SafetyAblation TechnologyElectroporation-based AblationProtocol-specified Safety AssessmentsPulsed Field AblationSafety In Ablation TherapySurgical AblationTissue Ablation
BACKGROUND: Unlike conventional microsecond pulsed electrical fields that primarily target the cell membranes, nanosecond pulses are thought to primarily electroporate intracellular organelles. We conducted a comprehensive preclinical assessment of catheter-based endocardial nanosecond pulsed field ablation in swine. METHODS: A novel endocardial nanosecond pulsed field ablation system was evaluated in a total of 25 swine. Using either a low-dose (5-second duration) or high-dose (15-second duration) strategy, thoracic veins and discrete atrial and ventricular sites were ablated. Predetermined survival periods were <1 (n=1), ≈2 (n=7), ≈7 (n=6), 14 (n=2), or ≈28 (n=9) days, and venous isolation was assessed before euthanasia. Safety assessments included evaluation of esophageal effects, phrenic nerve function, and changes in venous caliber. All tissues were subject to careful gross pathological and histopathologic examination. RESULTS: All (100%) veins (13 low-dose, 34 high-dose) were acutely isolated, and all reassessed veins (6 low-dose, 15 high-dose) were durably isolated. All examined vein lesions (10 low-dose, 22 high-dose) were transmural. Vein diameters (n=15) were not significantly changed. Of the animals assessed for phrenic palsy (n=9), 3 (33%) demonstrated only transient palsy. There were no differences between dosing strategies. Thirteen mitral isthmus lesions were analyzed, and all 13 (100%) were transmural (depth, 6.4±0.4 mm). Ventricular lesions were 14.7±4.5 mm wide and 7.1±1.3 mm deep, with high-dose lesions deeper than low-dose (7.9±1.2 versus 6.2±0.8 mm; P =0.007). The esophagus revealed nontransmural adventitial surface lesions in 5 of 5 (100%) animals euthanized early (2 days) post-ablation. In the 10 animals euthanized later (14–28 days), all animals demonstrated significant esophageal healing—8 with complete resolution, and 2 with only trace fibrosis. CONCLUSIONS: A novel, endocardial nanosecond pulsed field ablation system provides acute and durable venous isolation and linear lesions. Transient phrenic injury and nontransmural esophageal lesions can occur with worst-case assessments suggesting limits to pulsed field ablation tissue selectivity and the need for dedicated assessments during clinical studies.
20
Nanosecond, high‐intensity pulsed electric fields induce apoptosis in human cells
Stephen J. Beebe, P. Fox, Laura J. Rec et al. · The FASEB Journal · 2003 · 450 citations
Coronary Arterial Spasm During Pulsed Field Ablation to Treat Atrial Fibrillation
Vivek Y. Reddy, Jan Petrů, Moritoshi Funasako et al. · Circulation · 2022 · 257 citations · Full text
Pulsed Field Ablation Versus Radiofrequency Ablation
Jacob S. Koruth, Kenji Kuroki, Iwanari Kawamura et al. · Circulation Arrhythmia and Electrophysiology · 2020 · 212 citations · Full text
Medicine, Cardiology, Surgery +12