British Journal of Radiology · 2024 · 15 citations · 24 references
MedicineCardiologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyCardiovascular ImagingComputed TomographyCoronary AngiographyCoronary Artery ImagingImage Quality AssessmentMedical ImagingCoronary Ct AngiographyCoronary Imaging ArtifactsDeep Learning ReconstructionDeep Learning-based ReconstructionImage Noise AssessmentIterative ReconstructionSuper-resolutionSuper-resolution Reconstruction
OBJECTIVES: This study aimed to assess the impact of super-resolution deep learning reconstruction (SR-DLR) on coronary CT angiography (CCTA) image quality and blooming artifacts from coronary artery stents in comparison to conventional methods, including hybrid iterative reconstruction (HIR) and deep learning-based reconstruction (DLR). METHODS: A retrospective analysis included 66 CCTA patients from July to November 2022. Major coronary arteries were evaluated for image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Stent sharpness was quantified using 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD). Qualitative analysis employed a 5-point scoring system to assess overall image quality, image noise, vessel wall, and stent structure. RESULTS: SR-DLR demonstrated significantly lower image noise compared to HIR and DLR. SNR and CNR were notably higher in SR-DLR. Stent ERS was significantly improved in SR-DLR, with mean ERD values of 0.70 ± 0.20 mm for SR-DLR, 1.13 ± 0.28 mm for HIR, and 0.85 ± 0.26 mm for DLR. Qualitatively, SR-DLR scored higher in all categories. CONCLUSIONS: SR-DLR produces images with lower image noise, leading to improved overall image quality, compared with HIR and DLR. SR-DLR is a valuable image reconstruction algorithm for enhancing the spatial resolution and sharpness of coronary artery stents without being constrained by hardware limitations. ADVANCES IN KNOWLEDGE: The overall image quality was significantly higher in SR-DLR, resulting in sharper coronary artery stents compared to HIR and DLR.
24
Nonoperative Dilatation of Coronary-Artery Stenosis
A Grüntzig, A Senning, W Siegenthaler · New England Journal of Medicine · 1979 · 2.4K citations
Medicine, Cardiology, Surgery +13
Matthew J. Budoff, David A. Dowe, James G. Jollis et al. · Journal of the American College of Cardiology · 2008 · 2.1K citations
Medicine, Cardiology, Radiology +14
Armin Arbab‐Zadeh, Julie M. Miller, Carlos Eduardo Rochitte et al. · Journal of the American College of Cardiology · 2012 · 270 citations
Medicine, Cardiology, Radiology +17
Deep learning–based image restoration algorithm for coronary CT angiography
Fuminari Tatsugami, Toru Higaki, Yuko Nakamura et al. · European Radiology · 2019 · 264 citations
Medicine, Cardiology, Radiology +14