Eye and Vision · 2024 · 12 citations · 18 references
MedicineOphthalmologySurgeryClinical Vision ScienceOphthalmic SurgeryRefractive SurgeryAstigmatism CorrectionCataract SurgeryPostoperative Refractive OutcomesPreoperative Refractive EvaluationRefractive ErrorRefractive Error AssessmentAstigmatic OutcomeAstigmatism Correction AccuracyCorneal Astigmatism AssessmentMonocular Visual AcuityMonofocal Intraocular LensesOutcome MeasuresPostoperative AstigmatismSurgical Astigmatism
BACKGROUND: To assess clinical outcomes after implanting toric, extended-depth-of-focus intraocular lenses (IOLs) to correct low corneal astigmatism in eyes with cataracts. METHODS: 47 eyes were implanted with the AcrySof IQ Vivity Toric DFT215 IOL. Main outcome measures were refractive error, monocular uncorrected and corrected distance (UDVA/CDVA), uncorrected and distance-corrected intermediate (UIVA/DCIVA), and uncorrected near and distance-corrected near (UNVA/DCNVA) visual acuities, monocular defocus curve, rotational stability, and IOLSAT and QUVID questionnaires. Patients were assessed at 3 months postsurgery. RESULTS: All eyes had a postoperative spherical equivalent (SE) within ± 0.50 D and 97.87% (n = 46) had a refractive cylinder ≤ 0.50 D. The mean SE and refractive cylinder were - 0.10 ± 0.17 D and - 0.16 ± 0.24 D, respectively. The CDVA was ≥ 20/25 and ≥ 20/32 in 95.74% (n = 45) and 97.87% (n = 46) of eyes, respectively. The DCIVA was ≥ 20/32 in 85.11% (n = 40) of eyes and the DCNVA was ≥ 20/40 in 74.47% (n = 35). The mean values of CDVA, DCIVA, and DCNVA were - 0.02 ± 0.08, 0.14 ± 0.09, and 0.23 ± 0.12 logMAR, respectively. The defocus curve revealed good visual acuity at far and intermediate distances with a depth-of-focus of about 1.75 D. IOL rotation was 0.74 ± 1.13 degrees and all eyes had a rotation of less than 5 degrees. Patients reported either good or very good postoperative vision without eyeglasses under bright-light-conditions at distance (87.80%, 36/41) and intermediate distance (92.68%, 38/41). Between about 63.83%-72.34% (30-34) of patients reported no starburst, halos, or glare, or if experienced, were not bothersome. CONCLUSIONS: The Vivity toric IOL implanted in eyes with low-astigmatism provides accurate refractive outcomes, good visual acuity at different distances and excellent rotational stability. Trial Registration The study was registered with the German Clinical Trials Register (DRKS00030579).
18
The AcrySof Toric Intraocular Lens in Subjects with Cataracts and Corneal Astigmatism
Edward J. Holland, Stephen S. Lane, Jeffrey Horn et al. · Ophthalmology · 2010 · 269 citations
Medicine, Ophthalmology, Surgery +13
Prevalence of corneal astigmatism before cataract surgery in Chinese patients
Weirong Chen, Chengguo Zuo, Chuyin Chen et al. · Journal of Cataract & Refractive Surgery · 2012 · 127 citations
Medicine, Ophthalmology, Surgery +17