BACKGROUND: To investigate the use of high intensity focused ultrasound (HIFU) for great saphenous vein (GSV) incompetence. MATERIAL AND METHODS: Patients with GSV incompetence underwent HIFU. The primary endpoint was the rate of GSV target segment shrinkage or closure after 1 year. RESULTS: Out of 188 limbs treated, the GSV treated segment shrinkage/closure rate at 1 week, 3 months, 6 months, and 12 months was 93.3%, 98.2%, 97.6%, and 98.3%, respectively. CONCLUSION: These preliminary results suggest that HIFU holds promise for the treatment of GSV incompetence. Further trials are needed to compare it with other techniques and assess long-term outcomes.