EuroIntervention · 2024 · 17 citations · 27 references
MedicineCardiologyPharmacologyClinical PharmacologyDrug DeliveryPharmacodynamicsBalloon AngioplastyCardiovascular Drug SafetyCardiovascular PharmacodynamicsCardiovascular PharmacologyCoronary AngioplastyCoronary Artery DiseaseBalloon-expandable StentsCardiovascular Drug PharmacologyCoronary CalcificationDrug Loading EffectsHemodynamic Drug EffectsRabbit Cardiovascular Drug EffectsRabbit Clinical PharmacologyRabbit Pharmacodynamics
BACKGROUND: Drug-coated balloons (DCBs) are important treatment options for coronary artery disease; however, randomised controlled trials comparing various DCB technologies are sparse, and further investigations are needed. AIMS: This preclinical study aimed to histologically and biologically compare the drug effects and safety of a low-dose paclitaxel-coated DCB (PCB; AGENT), a regular-dose PCB (SeQuent Please NEO) and a sirolimus-coated DCB (SCB; MagicTouch). METHODS: The DCBs were inflated in the healthy iliac arteries of 18 rabbits, which were euthanised after 28 days. The treated iliac arteries and distal skeletal muscles were histopathologically evaluated, and drug concentrations were measured. RESULTS: In the histopathological evaluation, the medial smooth muscle cell loss score regarding depth, an indicator of drug efficacy, was significantly higher with AGENT and SeQuent Please NEO than with MagicTouch (4.0 [3.6-4.0] vs 3.7 [3.7-4.0] vs 2.2 [2.0-2.4]), with significant differences in comparisons between AGENT and MagicTouch (p<0.01) and between SeQuent Please NEO and MagicTouch (p<0.01). AGENT and SeQuent Please NEO showed comparable drug concentrations in the treated artery (p=0.61). In contrast, the drug concentrations in distal skeletal muscles were the highest for MagicTouch, followed by SeQuent Please NEO and AGENT (28.07 [13.19-52.46] ng/mg vs 0.66 [0.22-3.76] ng/mg vs 0.25 [0.04-3.23] ng/mg, respectively). CONCLUSIONS: This study demonstrated that PCBs might have higher efficacy and lower drug concentrations in distal skeletal muscles than the MagicTouch SCB. The efficacy of the AGENT low-dose PCB and the SeQuent Please NEO regular-dose PCB was comparable.
27
2018 ESC/EACTS Guidelines on myocardial revascularization
Franz‐Josef Neumann, Miguel Sousa‐Uva, Anders Ahlsson et al. · EuroIntervention · 2019 · 1.3K citations
Fernándo Alfonso, Marı́a José Pérez-Vizcayno, Alberto Cárdenas et al. · Journal of the American College of Cardiology · 2014 · 266 citations · Full text