Radiation Oncology · 2024 · 13 citations · 33 references
MedicineBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyAttention NetworksComputed TomographyHead ImagingMagnetic Resonance Image ReconstructionMagnetic Resonance ImagingMedical ImagingCt Image ReconstructionDeep Learning In RadiologyGenerative Image SynthesisHounsfield UnitsImage Feature RepresentationImage Quality MetricsSignal-to-noise RatioSimilarity Measures
BACKGROUND: Magnetic resonance imaging (MRI) plays an increasingly important role in radiotherapy, enhancing the accuracy of target and organs at risk delineation, but the absence of electron density information limits its further clinical application. Therefore, the aim of this study is to develop and evaluate a novel unsupervised network (cycleSimulationGAN) for unpaired MR-to-CT synthesis. METHODS: The proposed cycleSimulationGAN in this work integrates contour consistency loss function and channel-wise attention mechanism to synthesize high-quality CT-like images. Specially, the proposed cycleSimulationGAN constrains the structural similarity between the synthetic and input images for better structural retention characteristics. Additionally, we propose to equip a novel channel-wise attention mechanism based on the traditional generator of GAN to enhance the feature representation capability of deep network and extract more effective features. The mean absolute error (MAE) of Hounsfield Units (HU), peak signal-to-noise ratio (PSNR), root-mean-square error (RMSE) and structural similarity index (SSIM) were calculated between synthetic CT (sCT) and ground truth (GT) CT images to quantify the overall sCT performance. RESULTS: One hundred and sixty nasopharyngeal carcinoma (NPC) patients who underwent volumetric-modulated arc radiotherapy (VMAT) were enrolled in this study. The generated sCT of our method were more consistent with the GT compared with other methods in terms of visual inspection. The average MAE, RMSE, PSNR, and SSIM calculated over twenty patients were 61.88 ± 1.42, 116.85 ± 3.42, 36.23 ± 0.52 and 0.985 ± 0.002 for the proposed method. The four image quality assessment metrics were significantly improved by our approach compared to conventional cycleGAN, the proposed cycleSimulationGAN produces significantly better synthetic results except for SSIM in bone. CONCLUSIONS: We developed a novel cycleSimulationGAN model that can effectively create sCT images, making them comparable to GT images, which could potentially benefit the MRI-based treatment planning.
33
Unpaired Image-to-Image Translation Using Cycle-Consistent Adversarial Networks
Jun-Yan Zhu, Taesung Park, Phillip Isola et al. · 2017 · 21.9K citations · Full text
Radiotherapy planning using MRI
Maria A. Schmidt, Geoffrey S. Payne · Physics in Medicine and Biology · 2015 · 351 citations · Full text
Estimating CT Image from MRI Data Using 3D Fully Convolutional Networks
Dong Nie, Xiaohuan Cao, Yaozong Gao et al. · Lecture notes in computer science · 2016 · 259 citations · Full text