Clinical Chemistry · 2024 · 17 citations · 19 references
MedicineOncologyPathologyDiagnostic PathologyMolecular DiagnosticsMolecular PathologyBiomarkers In PathologyCancer BiomarkersDiagnostic EvaluationProstate-specific Antigen TestingTumor AntigensTumor MarkersBiomarker HarmonizationCancer Antigen 125Cancer Antigen 15-3Cancer Antigen 19-9ConsensusFeasibility Study DesignSerum Tumor MarkersTumor Marker Standardization
BACKGROUND: The harmonization status of most tumor markers (TMs) is unknown. We report a feasibility study performed to determine whether external quality assessment (EQA) programs can be used to obtain insights into the current harmonization status of the tumor markers α-fetoprotein (AFP), prostate specific antigen (PSA), carcinoembryonic antigen (CEA), cancer antigen (CA)125, CA15-3 and CA19-9. METHODS: EQA sample results provided by 6 EQA providers (INSTAND [Germany], Korean Association of External Quality Assessment Service [KEQAS, South Korea], National Center for Clinical Laboratories [NCCL, China], United Kingdom National External Quality Assessment Service [UK NEQAS, United Kingdom], Stichting Kwaliteitsbewaking Medische Laboratoriumdiagnostiek [SKML, the Netherlands], and the Royal College of Pathologists of Australasia Quality Assurance Programs [RCPAQAP, Australia]) between 2020 and 2021 were used. The consensus means, calculated from the measurement procedures present in all EQA programs (Abbott Alinity, Beckman Coulter DxI, Roche Cobas, and Siemens Atellica), was used as reference values. Per measurement procedure, the relative difference between consensus mean for each EQA sample and the mean of all patient-pool-based EQA samples were calculated and compared to minimum, desirable, and optimal allowable bias criteria based on biological variation. RESULTS: Between 19040 (CA15-3) and 25398 (PSA) individual results and 56 (PSA) to 76 (AFP) unique EQA samples were included in the final analysis. The mean differences with the consensus mean of patient-pool-based EQA samples for all measurement procedures were within the optimum bias criterion for AFP, the desirable bias for PSA, and the minimum bias criterion for CEA. However, CEA results <8 µg/L exceeded the minimum bias criterion. For CA125, CA15-3, and CA19-9, the harmonization status was outside the minimum bias criterion, with systematic differences identified. CONCLUSIONS: This study provides relevant information about the current harmonization status of 6 tumor markers. A pilot harmonization investigation for CEA, CA125, CA15-3, and CA19-9 would be desirable.
19
Hepatocellular carcinoma: ESMO Clinical Practice Guidelines for diagnosis, treatment and follow-up
Arndt Vogel, Andrés Cervantes, Ian Chau et al. · Annals of Oncology · 2018 · 1.1K citations · Full text
Prostate cancer: ESMO Clinical Practice Guidelines for diagnosis, treatment and follow-up
Chris Parker, Elena Castro, Karim Fizazi et al. · Annals of Oncology · 2020 · 953 citations · Full text
Takayuki Yoshino, Dirk Arnold, Hiroya Taniguchi et al. · Annals of Oncology · 2017 · 592 citations · Full text
D. Planchard, Shun Lü, Hao Sun et al. · Annals of Oncology · 2018 · 299 citations · Full text
Medicine, Oncology, Metastasis +15