IEEE Transactions on Biomedical Engineering · 2024 · 44 citations · 34 references
EngineeringBioengineeringBiomedical EngineeringBiosensorsOptical MaterialsSensorsDielectricsElectromagnetic WavesLight-tissue InteractionOptical ResonatorsRefractive IndexTerahertz PhotonicsBiological SensingCavity ResonatorsElectromagnetically Induced TransparencyMetasurfacesQ FactorRefractive Index SensingSensingTerahertz Metamaterials
Terahertz (THz) metasurfaces based on high Q-factor electromagnetically induced transparency-like (EIT-like) resonances are promising for biological sensing. Despite this potential, they have not often been investigated for practical differentiation between cancerous and healthy cells. The present methodology relies mainly on refractive index sensing, while factors of transmission magnitude and Q-factor offer significant information about the tumors. To address this limitation and improve sensitivity, we fabricated a THz EIT-like metasurface based on asymmetric resonators on an ultra-thin and flexible dielectric substrate. Bright-dark modes coupling at 1.96 THz was experimentally verified, and numerical results and theoretical analysis were presented. An enhanced theoretical sensitivity of 550 GHz/RIU was achieved for a sample with a thickness of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$13\mu m$</tex-math></inline-formula> due to the ultra-thin substrate and novel design. A two-layer skin model was generated whereby keratinocyte cell lines were cultured on a base of collagen. When NEB1-shPTCH (basal cell carcinoma (BCC)) were switched out for NEB1-shCON cell lines (healthy) and when BCC's density was raised from <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$1\times 10^{5}$</tex-math></inline-formula> to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$2.5\times 10^{5}$</tex-math></inline-formula> , a frequency shift of 40 and 20 GHz were observed, respectively. A combined sensing analysis characterizes different cell lines. The findings may open new opportunities for early cancer detection with a fast, less-complicated, and inexpensive method.
34
Plasmonic analogue of electromagnetically induced transparency at the Drude damping limit
Na Liu, Lutz Langguth, Jürgen Kästel et al. · Nature Materials · 2009 · 1.8K citations
Classical analog of electromagnetically induced transparency
American Journal of Physics · 2002 · 579 citations · Full text
Real-time terahertz imaging with a single-pixel detector
Rayko I. Stantchev, Xiao Yu, Thierry Blu et al. · Nature Communications · 2020 · 481 citations · Full text
Engineering, Biomedical Engineering, Electrical Engineering +17