Chemical Engineering Journal · 2024 · 13 citations · 50 references
Natural SciencesMaterials SciencePharmaceutical AnalysisBiosensorsElectroanalytical MethodsNanomaterialsChemical SensorsChiral RecognitionChiral SeparationLigand BindingMolecular SensorsNanosensorsChiral Ligand RecognitionChiral Recognition In NanomaterialsChiral Recognition MechanismsChirality DeterminationElectron TransferEnantioselective DetectionMolecular Simulation AnalysisTransfer Efficiency
Chirality recognition by monitoring electrochemiluminescence/chemiluminescence (CL) signals of probes altered by enantiomers is considered a promising method in the fields of pharmaceuticals and biotechnology. However, improving the sensitivity of chiral recognition and accurately elucidating its chiral recognition mechanism are still two major challenges. Herein, L-Cys-modified chiral Au nanorod (L-GNR) vertical arrays-enhanced CL sensing is proposed for improving the sensitivity of chiral naproxen recognition and accurately elucidating its chiral recognition mechanism. The resulting L-GNR vertical arrays exhibited a strong local electric field and improved electron transfer efficiency, thereby enhancing the CL signal of the luminol-H 2 O 2 system. More importantly, such L-GNR vertical arrays exhibited markedly different CL intensities toward chiral drug R/S-naproxen (R/S-NPx) due to the different affinity between L-Cys and R/S-NPx, which was confirmed by molecular dynamics simulation. Thus, an ultrasensitive enantioselective recognition of R/S-NPx was achieved by the L-GNR vertical arrays exhibiting a CL signal for S-NPx that was approximately 2.5-fold higher than that of R-NPx, with a limit of detection as low as 0.14 pM for R-NPx and 0.097 pM for S-NPx, respectively. The mechanism of the stereospecific interaction between the naproxen enantiomers and the chiral GNR vertical arrays was investigated by scanning electrochemical microscopy (SECM). We found that the electron transfer rate of identification system determined strength of the CL signals. The electron transfer rate of L-GNR vertical arrays + R-NPx was faster than that of the L-GNR vertical arrays + S-NPx due to the weaker interaction between L-GNR vertical arrays and R-NPx compared to L-GNR vertical arrays and S-NPx. This study not only provides a novel strategy for the detection of enantiomers but also reveals the mechanism of enantioselective recognition through SECM .
50
Amino-acid- and peptide-directed synthesis of chiral plasmonic gold nanoparticles
Hye‐Eun Lee, Hyo‐Yong Ahn, Jungho Mun et al. · Nature · 2018 · 1.2K citations
Natural Sciences, Materials Engineering, Materials Science +14
Hanjun Sun, Andong Zhao, Nan Gao et al. · Angewandte Chemie International Edition · 2015 · 523 citations
Gold Nanoparticle-Catalyzed Luminol Chemiluminescence and Its Analytical Applications
Zhifeng Zhang, Hua Cui, Chun‐Ze Lai et al. · Analytical Chemistry · 2005 · 501 citations