Expert Systems with Applications · 2024 · 19 citations · 92 references
EngineeringBioengineeringBiomedical EngineeringBiomedical Signal ProcessingMachine LearningNeural EngineeringBiomedical Signal ModelingCardiac Signal ProcessingGenerative ModelingImage RestorationSignal ProcessingWearable Health TechnologiesGenerative Adversarial NetworksHeart RateHeart Rate MeasurementHeart Rate MonitoringMotion ArtifactsPhotoplethysmogram Signal ProcessingSignalsWearable Devices
Physiological signals, such as the Photoplethysmogram (PPG) collected through wearable devices, consistently encounter significant motion artifacts. Current signal processing techniques, and even state-of-the-art machine learning algorithms, frequently struggle to effectively restore the inherent bodily signals amidst the array of randomly generated distortions. This often leads to the modification or even the degradation of the underlying physiological information. To enhance heart rate estimation from wrist PPG (wPPG) signals, this study introduces the Translation Through Restoration GAN (TTR-GAN). TTR-GAN comprises cascaded dual-stage 1D Cycle Generative Adversarial Networks (1D-CycleGANs) constructed using Super-ONNs. In the first phase, corrupted wPPG waveforms are blindly restored using a 1D-CycleGAN-based restoration framework. Subsequently, in the second phase, the restored wPPG waveforms are translated into clean finger PPG (fPPG) signals through a 1D-CycleGAN-based signal-to-signal translation or synthesis framework. Both the restorer and translator GANs undergo independent evaluation using robust temporal, spectral, and clinical metrics. The application of the multipass restoration scheme to the wPPG signals resulted in significantly lower entropy compared to the raw wPPGs, indicating reduced irregularity. Using the proposed PRTX metric to evaluate the translational ability of the multichannel translator CycleGAN, we achieved a substantial improvement of 35.88% in wrist-to-finger PPG translation. The correlation between the pulse rate and pulse rate variations estimated from the generated fPPG signals and the heart rate and heart rate variability readings from the ground truth ECG improved by approximately 10.4% and 14.7%, respectively, when compared to the raw wPPG signals. The proposed TTR-GAN can be implemented in wearable devices to obtain reliable real-time cardiovascular data during daily activities.
92
Unpaired Image-to-Image Translation Using Cycle-Consistent Adversarial Networks
Jun-Yan Zhu, Taesung Park, Phillip Isola et al. · 2017 · 21.9K citations · Full text
MIMIC-III, a freely accessible critical care database
Alistair E. W. Johnson, Tom Pollard, Lu Shen et al. · Scientific Data · 2016 · 8.1K citations · Full text
Least Squares Generative Adversarial Networks
Xudong Mao, Qing Li, Haoran Xie et al. · 2017 · 5.2K citations