Investigative Radiology · 2024 · 14 citations · 29 references
Veterinary MedicineRadiologySurgeryBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyComputed TomographyImage QualityImage Quality AssessmentImage Quality AssuranceMedical ImagingRadiographic ImagingArtifact ReductionArtifact SuppressionImage ArtifactsImage Distortion CorrectionMetal Artifact CorrectionMetal Artifact ReductionMetallic ImplantsReconstruction Of Metal Artifacts
OBJECTIVES: The aim of this study was to introduce and evaluate a new metal artifact reduction framework (iMARv2) that addresses the drawbacks (residual artifacts after correction and user preferences for image quality) associated with the current clinically applied iMAR. MATERIALS AND METHODS: A new iMARv2 has been introduced, combining the current iMAR with new modular components to remove residual metal artifacts after image correction. The postcorrection image impression is adjustable with user-selectable strength settings. Phantom scans from an energy-integrating and a photon-counting detector CT were used to assess image quality, including a Gammex phantom and anthropomorphic phantoms. In addition, 36 clinical cases (with metallic implants such as dental fillings, hip replacements, and spinal screws) were reconstructed and evaluated in a blinded and randomized reader study. RESULTS: The Gammex phantom showed lower HU errors compared with the uncorrected image at almost all iMAR and iMARv2 settings evaluated, with only minor differences between iMAR and the different iMARv2 settings. In addition, the anthropomorphic phantoms showed a trend toward lower errors with higher iMARv2 strength settings. On average, the iMARv2 strength 3 performed best of all the clinical reconstructions evaluated, with a significant increase in diagnostic confidence and decrease in artifacts. All hip and dental cases showed a significant increase in diagnostic confidence and decrease in artifact strength, and the improvements from iMARv2 in the dental cases were significant compared with iMAR. There were no significant improvements in the spine. CONCLUSIONS: This work has introduced and evaluated a new method for metal artifact reduction and demonstrated its utility in routine clinical datasets. The greatest improvements were seen in dental fillings, where iMARv2 significantly improved image quality compared with conventional iMAR.
29
CT artifacts: causes and reduction techniques
F. Edward Boas, Dominik Fleischmann · Imaging in Medicine · 2012 · 817 citations
Reduction of CT artifacts caused by metallic implants.
Willi A. Kalender, R. Hebel, J. C. W. Ebersberger · Radiology · 1987 · 743 citations
Normalized metal artifact reduction (NMAR) in computed tomography
Esther Meyer, Rainer Raupach, Michael Lell et al. · Medical Physics · 2010 · 599 citations · Full text
Frequency split metal artifact reduction (FSMAR) in computed tomography
Esther Meyer, Rainer Raupach, Michael Lell et al. · Medical Physics · 2012 · 259 citations