Critical Care Explorations · 2023 · 37 citations · 16 references
Veterinary MedicineInternal MedicineDiagnostic ImagingFluid DynamicsUltrasonographyFluid ManagementHemodynamic SupportHemodynamicsPoint-of-care UltrasonographyPoint-of-care UltrasoundDynamic Fluid Responsiveness AssessmentFluid Responsiveness TestingFluid Status EvaluationFrank-starling MechanismFrank-starling RelationshipHemodynamic UltrasoundPassive Leg Raise TestPassive Leg Raising
Point of care ultrasound (POCUS) is a first-line tool to assess hemodynamically unstable patients, however, there is confusion surrounding intertwined concepts such as: “flow,” “congestion,” “fluid responsiveness (FR),” and “fluid tolerance.” We argue that the Frank–Starling relationship is clarifying because it describes the interplay between “congestion” and “flow” on the x -axis and y -axis, respectively. Nevertheless, a single, simultaneous assessment of congestion and flow via POCUS remains a static approach. To expand this, we propose a two-step process. The first step is to place the patient on an ultrasonographic Diamond–Forrester plot. The second step is a dynamic assessment for FR (e.g., passive leg raise), which individualizes therapy across the arc of critical illness.
16
Glenn Hernández, Gustavo A. Ospina‐Tascón, Lucas Petri Damiani et al. · JAMA · 2019 · 872 citations · Full text
Team Management of Patients With Heart Failure
Kathleen L. Grady, Kathleen Dracup, Gemma T. Kennedy et al. · Circulation · 2000 · 408 citations · Full text