Neuro-Oncology Advances · 2023 · 17 citations · 22 references
MedicineOncologyRadiologyDiagnostic ImagingDiagnostic RadiologyNeuro-oncologyBrain MetastasesBrain MetastasisMagnetic Resonance ImagingNeuro-oncology ImagingResponse AssessmentTherapy Response AssessmentImaging Response CriteriaNeuroimaging Of Brain MetastasesT1-weighted ImagingThree-dimensional Volumetric AnalysisTreatment Response CriteriaTumor Volume EstimationTumor Volume MeasurementVolumetric Response Analysis
Background: The Response Assessment in Neuro-Oncology for Brain Metastases (RANO-BM) criteria are the gold standard for assessing brain metastases (BMs) treatment response. However, they are limited by their reliance on 1D, despite the routine use of high-resolution T1-weighted MRI scans for BMs, which allows for 3D measurements. Our study aimed to investigate whether volumetric measurements could improve the response assessment in patients with BMs. Methods: We retrospectively evaluated a dataset comprising 783 BMs and analyzed the response of 185 of them from 132 patients who underwent stereotactic radiotherapy between 2007 and 2021 at 5 hospitals. We used T1-weighted MRIs to compute the volume of the lesions. For the volumetric criteria, progressive disease was defined as at least a 30% increase in volume, and partial response was characterized by a 20% volume reduction. Results: Our study showed that the proposed volumetric criteria outperformed the RANO-BM criteria in several aspects: (1) Evaluating every lesion, while RANO-BM failed to evaluate 9.2% of them. (2) Classifying response effectively in 140 lesions, compared to only 72 lesions classified by RANO-BM. (3) Identifying BM recurrences a median of 3.3 months earlier than RANO-BM criteria. Conclusions: Our study demonstrates the superiority of volumetric criteria in improving the response assessment of BMs compared to the RANO-BM criteria. Our proposed criteria allow for evaluation of every lesion, regardless of its size or shape, better classification, and enable earlier identification of progressive disease. Volumetric criteria provide a standardized, reliable, and objective tool for assessing treatment response.
22
New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1)
E. Eisenhauer, P. Therasse, Jan Bogaerts et al. · European Journal of Cancer · 2008 · 29.5K citations
Reproducibility of radiomics for deciphering tumor phenotype with imaging
Binsheng Zhao, Yongqiang Tan, Wei‐Yann Tsai et al. · Scientific Reports · 2016 · 513 citations · Full text
Test–Retest Reproducibility Analysis of Lung CT Image Features
Yoganand Balagurunathan, Virendra Kumar, Yuhua Gu et al. · Journal of Digital Imaging · 2014 · 265 citations · Full text
Gaurav Shah, Santosh Kesari, Ronghui Xu et al. · Neuro-Oncology · 2006 · 195 citations · Full text