Advances in Radiation Oncology · 2023 · 11 citations · 21 references
MedicineGynecologyRadiation OncologyDiagnostic ImagingGynecologic OncologyTreatment PlanningCancer Treatment PlanningComputed TomographyRadiation TherapyRadiation Treatment PlanningTarget Volume DelineationAnatomic ContoursAutomated Treatment PlanningBrachytherapy ContouringComputed Tomography Based ContouringContouringGynecologic ContouringRadiation Oncology ContouringSurface Contours
PurposeThe use of deep learning to auto-contour organs-at-risk (OARs) in gynecologic radiation treatment is well-established. Yet, there is limited data investigating the prospective use of auto-contouring in clinical practice. In this study, we assess the accuracy and efficiency of auto-contouring OARs for CT-based brachytherapy treatment planning of gynecologic malignancies.Materials and MethodsAn in-house contouring tool automatically delineated five OARs in gynecologic radiation treatment planning: the bladder, small bowel, sigmoid, rectum, and urethra. Accuracy of each auto-contour was evaluated using a 5-point Likert scale: a score of five indicated the contour could be used without edits, while a score of one indicated the contour was unusable. During scoring, automated contours were edited and subsequently used for treatment planning. Dice similarity coefficient (DSC), mean surface distance (MSD), 95% Hausdorff Distance (95HD), Hausdorff Distance (HD), and dosimetric changes between original and edited contours were calculated. Contour approval time and total planning time of a prospective auto-contoured (AC) cohort were compared to times from a retrospective manually contoured (MC) cohort.ResultsThirty AC cases from January 2022 to July 2022 and thirty-one MC cases from July 2021 to January 2022 were included. The mean (±SD) Likert score for each OAR was the following: bladder 4.77 (±0.58), small bowel 3.96 (±0.91), sigmoid colon 3.92 (±0.81), rectum 4.6 (±0.71), and urethra 4.27 (±0.78). No auto-contours required major edits. All OARs had a mean DSC > 0.86, MSD < 0.48mm, 95HD < 3.2mm, and HD < 10.32mm between original and edited contours. There was no significant difference in DVH metrics (D2.0cc/D0.1cc) between original and edited contours (p-values > 0.05). The average time to plan approval in the AC cohort was 19% less than the MC cohort. (AC vs. MC, 117.0 + 18.0 minutes versus 144.9 ± 64.5 minutes, p=0.045).ConclusionsAutomated contouring is useful and accurate in clinical practice. Auto-contouring OARs streamlines radiation treatment workflows and decreases time required to design and approve gynecologic brachytherapy plans.
21
Measures of the Amount of Ecologic Association Between Species
Lee R. Dice · Ecology · 1945 · 11.9K citations
Deep Learning for Automated Contouring of Primary Tumor Volumes by MRI for Nasopharyngeal Carcinoma
Li Lin, Qi Dou, Yueming Jin et al. · Radiology · 2019 · 346 citations
Segmentation of organs-at-risk in cervical cancer CT images with a convolutional neural network
Zhikai Liu, Xia Liu, Bin Xiao et al. · Physica Medica · 2020 · 118 citations · Full text