Diagnostic Pathology · 2023 · 10 citations · 27 references
MedicineOncologyPathologyBreast OncologySurgical OncologyTumor PathologyBreast CytologyBreast PathologyImmunohistochemistryTumor MarkersBreast Cancer HistopathologyLong-term Sample StorageLong-term Storage StrategiesParaffin EmbeddingPreservation Time OptimizationRoom-temperature StorageStorageStorage Time Limits
BACKGROUND: PD-L1 staining using long-stored paraffin sections may not be consistent with the true PD-L1 expression of patients. Therefore, it is necessary to explore the expression of PD-L1(SP142) in paraffin sections of invasive breast cancer with different storage times and the optimal storage temperature for unstained paraffin sections. METHODS: The study included 71 cases of PD-L1(SP142) positive breast cancer. The unstained paraffin sections were stored at room temperature conditions (20-25 °C), 4 °C, -20 °C and - 80 °C, respectively. PD-L1 staining was performed at 1, 2, 3, 4, 8, 12 and 24 weeks of storage. PD-L1 expression was assessed with a continuity score. RESULTS: The PD-L1 antigen was gradually lost as the storage time of paraffin sections increased. The PD-L1 positivity rate was 97.18% at 1 week for the sections stored at room temperature, and decreased from 83.10 to 71.83% for the sections stored for 2 weeks to 4 weeks, and 61.97%, 54.93%, and 32.93% for 8, 12, and 24 weeks, respectively. When stored at low temperatures of 4 °C, -20 °C and - 80 °C, the positivity rate decreases with the same trend but more slowly compared to room temperature. The mean IC score of PD-L1 also showed a gradual decrease in all cases. In the consistency analysis, PD-L1 expression in slices stored at room temperature for 2 weeks was consistent with PD-L1 expression in fresh slices (ICC ≥ 0.9 for all slices), and PD-L1 expression in slices stored at 4 °C or -20 °C for 4 weeks was consistent with PD-L1 expression in fresh slices (ICC ≥ 0.9 for all slices). When stored under refrigeration at -80 °C, PD-L1 expression in slices stored for 3 weeks was consistent with that in fresh slices (ICC ≥ 0.9). CONCLUSIONS: To our knowledge, this is the first article on the effect of preservation time and preservation temperature of paraffin sections on PD-L1 expression in breast cancer. Long-term storage of paraffin sections of unstained invasive breast cancer can lead to antigen loss of PD-L1 (SP142). Refrigerated storage of paraffin sections can delay antigen loss, with best results at 4 °C or -20 °C, and a storage time of no more than 4 weeks is recommended.
27
Predictive correlates of response to the anti-PD-L1 antibody MPDL3280A in cancer patients
Roy S. Herbst, Jean‐Charles Soria, Marcin Kowanetz et al. · Nature · 2014 · 5.3K citations
Medicine, Immunology, Oncology +16
Atezolizumab and Nab-Paclitaxel in Advanced Triple-Negative Breast Cancer
Peter Schmid, Sylvia Adams, Hope S. Rugo et al. · New England Journal of Medicine · 2018 · 4.4K citations · Full text
Medicine, Oncology, Pharmacology +17