Circulation Arrhythmia and Electrophysiology · 2023 · 18 citations · 9 references
MedicineCardiologyElectrophysiologyInterventional CardiologySurgical InstrumentationAblation TherapyCatheter AblationAblation TechnologyCollateral Damage AssessmentCollateral Damage EstimationPercutaneous AblationPulsed Field AblationPulsed Radiofrequency AblationRadiofrequency PulsesSurgical Ablation
BACKGROUND: Pulsed field ablation (PFA) has emerged as an alternative to radiofrequency ablation. However, data on focal point-by-point PFA are scarce. The aim of this study was to compare lesion durability and collateral damage between focally delivered unipolar/biphasic PFA versus radiofrequency in swine. METHODS: Eighteen swine were randomized to low-dose PFA, high-dose PFA, and radiofrequency using a multimodality generator. Radiofrequency delivered by market-available generator served as control group. A contact force-sensing catheter was used to focally deliver PFA/radiofrequency at the pulmonary veins and other predefined sites in the atria. Animals were remapped postprocedurally and 28 days postablation to test lesion durability followed by gross necroscopy and histology. RESULTS: All targeted sites were successfully ablated (contact force value, 13.9±4.1 g). Follow-up remapping showed persistent pulmonary vein isolation in all animals (100%) with lesion durability at nonpulmonary vein sites proven in most (98%). Regardless of the energy source used, the lesion size was similar across the study groups. Transmurality was achieved in 95% of targeted sites and 100% at pulmonary veins. On histology, PFA animals showed more mature scar formation than their radiofrequency counterpart without myocardial necrosis or inflammation. Finally, no sign of collateral damage was observed in any of the groups. CONCLUSIONS: In a randomized preclinical study, focally delivered unipolar/biphasic PFA guided by contact force values was associated with durable lesions on chronic remapping and with mature scar formation on histology without signs of collateral injury on necroscopy. Further studies are needed to investigate the long-term feasibility of this new approach to atrial fibrillation treatment.
9
Ablation of Atrial Fibrillation With Pulsed Electric Fields
Vivek Y. Reddy, Jacob S. Koruth, Jan Petrů et al. · JACC. Clinical electrophysiology · 2018 · 294 citations
Intracardiac pulsed field ablation: Proof of feasibility in a chronic porcine model
Mark T. Stewart, David E. Haines, Atul Verma et al. · Heart Rhythm · 2018 · 213 citations · Full text
Preclinical Evaluation of Pulsed Field Ablation
Jacob S. Koruth, Kenji Kuroki, Jin Iwasawa et al. · Circulation Arrhythmia and Electrophysiology · 2019 · 209 citations · Full text
Medicine, Cardiology, Anesthesia +14
Characterization of Phrenic Nerve Response to Pulsed Field Ablation
Brian Howard, David E. Haines, Atul Verma et al. · Circulation Arrhythmia and Electrophysiology · 2022 · 92 citations · Full text
Medicine, Cardiology, Anesthesia +11