Biomedicines · 2023 · 19 citations · 38 references
DentistryImplant DentistryProsthodonticsBone AugmentationImplant ProsthodonticsImplant SurgeryImplant BiomechanicsImplant Site AssessmentAlveolar Crest LevelBiomechanical LoadingBiomechanics Of Dental ImplantsCortical Bone StructureDental Implant BiomechanicsDental ImplantsImplant Stress DistributionThree-dimensional Implant Positioning
The issue of dental implant placement relative to the alveolar crest, whether in supracrestal, equicrestal, or subcrestal positions, remains highly controversial, leading to conflicting data in various studies. Three-dimensional (3D) Finite Element Analysis (FEA) can offer insights into the biomechanical aspects of dental implants and the surrounding bone. A 3D model of the jaw was generated using computed tomography (CT) scans, considering a cortical thickness of 1.5 mm. Subsequently, Morse cone implant-abutment connection implants were virtually positioned at the model's center, at equicrestal (0 mm) and subcrestal levels (-1 mm and -2 mm). The findings indicated the highest stress within the cortical bone around the equicrestally placed implant, the lowest stress in the -2 mm subcrestally placed implant, and intermediate stresses in the -1 mm subcrestally placed implant. In terms of clinical relevance, this study suggested that subcrestal placement of a Morse cone implant-abutment connection (ranging between -1 and -2 mm) could be recommended to reduce peri-implant bone resorption and achieve longer-term implant success.
38
Joke Duyck, I. Naert, Hans Jacob Rønold et al. · Clinical Oral Implants Research · 2001 · 414 citations · Full text
Dietmar Weng, Maria José Hitomi Nagata, Matthias Bell et al. · Clinical Oral Implants Research · 2008 · 163 citations