CardioVascular and Interventional Radiology · 2023 · 14 citations · 23 references
MedicineRadiologySurgeryInterventional RadiologyRadiation DosimetryRadiation SafetyAortic ImagingEndovascular SurgeryPatient Radiation SafetyPatient-specific DosimetryRadiation Risk AssessmentRadiation TherapyEndovascular Vascular RepairFenestrated Endovascular RepairInterventional Abdominal RadiologyIonizing Radiation Exposure AssessmentMedical Radiation Safety AssessmentProcedure-related Radiation SafetyRadiation Dose AssessmentRadiation Dose Management
Abstract Purpose Endovascular aortic repair (EAR) interventions, endovascular abdominal aortic repair (EVAR) and thoracic endovascular aortic repair (TEVAR), are associated with significant radiation exposures. We aimed to investigate the radiation doses from real-world practice and propose diagnostic reference level (DRL) for the UK. Materials and Methods Radiation data and essential demographics were retrospectively collected from 24 vascular and interventional radiology centres in the UK for all patients undergoing EAR—standard EVAR or complex, branched/fenestrated (BEVAR/FEVAR), and TEVAR—between 2018 and 2021. The data set was further categorised according to X-ray unit type, either fixed or mobile. The proposed national DRL is the 75th percentile of the collective medians for procedure KAP (kerma area product), cumulative air kerma (CAK), fluoroscopy KAP and CAK. Results Data from 3712 endovascular aortic procedures were collected, including 2062 cases were standard EVAR, 906 cases of BEVAR/FEVAR and 509 cases of TEVAR. The majority of endovascular procedures (3477/3712) were performed on fixed X-ray units. The proposed DRL for KAP was 162 Gy cm 2 , 175 Gy cm 2 and 266 Gy cm 2 for standard EVAR, TEVAR and BEVAR/FEVAR, respectively. Conclusion The development of DRLs is pertinent to EAR procedures as the first step to optimise the radiation risks to patients and staff while maintaining the highest patient care and paving the way for steps to reduce radiation exposures.
23
ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
E. Vañó, D.L. Miller, C J Martin et al. · Annals of the ICRP · 2017 · 981 citations
Guidelines for Patient Radiation Dose Management
Stephen Balter, Richard B. Towbin, Donald L. Miller et al. · Journal of Vascular and Interventional Radiology · 2009 · 441 citations
Douglas W. Fletcher, Donald L. Miller, Stephen Balter et al. · Journal of Vascular and Interventional Radiology · 2002 · 131 citations