Analytical Chemistry · 2023 · 19 citations · 29 references
Life SciencesBioinformaticsChemistryAnalytical ChemistryMass Spectrometric AnalysisMetabolomicsMass SpectrometryMass Spectrometry Data AnalysisMass Spectrometry-based MetabolomicsMetabolite AnnotationMetabolomics Data AnalysisMetabolomics Quality ControlAutomated Curation PipelinesMetabolite LibrariesReference Spectra LibrariesSpectral Library GenerationSpectral Library MatchingSpectral MatchingSpectral QualitySpectral Quality Assessment
Compound annotation using spectral-matching algorithms is vital for (MS/MS)-based metabolomics research, but is hindered by the lack of high-quality reference MS/MS library spectra. Finding and removing errors from libraries, including noise ions, is mostly done manually. This process is both error-prone and time-consuming. To address these challenges, we have developed an automated library curation pipeline, LibGen, to universally build novel spectral libraries. This pipeline corrects mass errors, denoises spectra by subformula assignments, and performs quality control of the reference spectra by calculating explained intensity and spectral entropy. We employed LibGen to generate three high-quality libraries with chemical standards of 2241 natural products. To this end, we used an IQ-X orbital ion trap mass spectrometer to generate 1947 classic high-energy collision dissociation spectra (HCD) as well as 1093 ultraviolet-photodissociation (UVPD) mass spectra. The third library was generated by an electron-activated collision dissociation (EAD) 7600 ZenoTOF mass spectrometer yielding 3244 MS/MS spectra. The natural compounds covered 140 chemical classes from prenol lipids to benzypyrans with >97% of the compounds showing <0.2 Tanimoto-similarity, demonstrating a very high structural variance. Mass spectra showed much higher information content for both UVPD- and EAD-mass spectra compared to classic HCD spectra when using spectral entropy calculations. We validated the denoising algorithm by acquiring MS/MS spectra at high concentration and at 13-fold diluted chemical standards. At low concentrations, a higher proportion of spectra showed apparent fragment ions that could not be explained by subformula losses of the parent molecule. When more than 10% of the total intensity of MS/MS fragments was regarded as noise ions, spectra were considered as low quality and were not included in the libraries. As the overall process is fully automated, LibGen can be utilized by all researchers who create or curate mass spectral libraries. The libraries we created here are publicly available at MassBank.us.
29
Proposed minimum reporting standards for chemical analysis
Lloyd W. Sumner, Alexander Amberg, Michael H. Beale et al. · Metabolomics · 2007 · 5K citations · Full text
MS-DIAL: data-independent MS/MS deconvolution for comprehensive metabolome analysis
Hiroshi Tsugawa, Tomáš Čajka, Tobias Kind et al. · Nature Methods · 2015 · 3.4K citations · Full text
Life Sciences, Biochemistry, Mass Spectrometric Analysis +13
Metabolomics – the link between genotypes and phenotypes
Oliver Fiehn · Plant Molecular Biology · 2002 · 3.4K citations
Sunghwan Kim, Jie Chen, Tiejun Cheng et al. · Nucleic Acids Research · 2022 · 3.2K citations · Full text