Journal of Vascular Surgery Cases and Innovative Techniques · 2023 · 25 citations · 10 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologyVascular SurgeryAcute Aortic SyndromesAneurysm RepairAortic Aneurysm RepairAortic SurgeryEndovascular SurgeryThoracic SurgeryAcute Aortic DissectionBlunt Thoracic InjuryBlunt Thoracic TraumaEndovascular Aortic Aneurysm RepairRuptured Aortic Aneurysm RepairSubclavian Artery SurgeryThoracic Aortic Aneurysm RepairThoracic Aortic Injury
The Gore TAG thoracic branch endoprosthesis (TBE) is the first Food and Drug Administration-approved device for zone 2 thoracic endovascular aortic repair, allowing for graft placement proximal to the left subclavian artery origin and maintaining vessel patency through a side branch. We describe our experience with the Gore TBE device in 20 patients for acute indications, including blunt thoracic aortic injuries, complicated dissections, and ruptured aneurysms. Technical success, with exclusion of pathology and left subclavian patency, was 100% without major complications within 30 days. Our early Gore TBE device experience demonstrates safe use in acute aortic pathology without an increased risk of complications.
10
Reporting standards for thoracic endovascular aortic repair (TEVAR)
Mark F. Fillinger, Roy K. Greenberg, James F. McKinsey et al. · Journal of Vascular Surgery · 2010 · 688 citations · Full text
Medicine, Cardiology, Surgery +14
Richard E. Redlinger, Sadaf S. Ahanchi, Jean M. Panneton · Journal of Vascular Surgery · 2013 · 182 citations
Himanshu J. Patel, Michael D. Dake, Joseph E. Bavaria et al. · The Annals of Thoracic Surgery · 2016 · 156 citations · Full text
Medicine, Cardiology, Surgery +15