EJNMMI Physics · 2023 · 37 citations · 23 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyRadiation DosimetryComputed TomographyComputed Tomography PhysicsIn Vivo DosimetryMedical ImagingPhantom DosimetryProtocol OptimizationAccuracyComputed Tomography Phantom DosimetryExpectation-maximizationExpectation-maximization AlgorithmImage Reconstruction AlgorithmsPersonalized Radiopharmaceutical TherapyReconstruction AlgorithmsRegularization
Abstract Background Dosimetry after radiopharmaceutical therapy with 177 Lu ( 177 Lu-RPT) relies on quantitative SPECT/CT imaging, for which suitable reconstruction protocols are required. In this study, we characterized for the first time the quantitative performance of a ring-shaped CZT-based camera using two different reconstruction algorithms: an ordered subset expectation maximization (OSEM) and a block sequential regularized expectation maximization (BSREM) combined with noise reduction regularization. This study lays the foundations for the definition of a reconstruction protocol enabling accurate dosimetry for patients treated with 177 Lu-RPT. Methods A series of 177 Lu-filled phantoms were acquired on a StarGuide™ (GE HealthCare), with energy and scatter windows centred at 208 (± 6%) keV and 185 (± 5%) keV, respectively. Images were reconstructed with the manufacturer implementations of OSEM (GE-OSEM) and BSREM (Q.Clear) algorithms, and various combinations of iterations and subsets. Additionally, the manufacturer-recommended Q.Clear-based reconstruction protocol was evaluated. Quantification accuracy, measured as the difference between the SPECT-based and the radionuclide calibrator-based activity, and noise were evaluated in a large cylinder. Recovery coefficients (RCs) and spatial resolution were assessed in a NEMA IEC phantom with sphere inserts. The reconstruction protocols considered suitable for clinical applications were tested on a cohort of patients treated with [ 177 Lu]Lu-PSMA-I&T. Results The accuracy of the activity from the cylinder, although affected by septal penetration, was < 10% for all reconstructions. Both algorithms featured improved spatial resolution and higher RCs with increasing updates at the cost of noise build-up, but Q.Clear outperformed GE-OSEM in reducing noise accumulation. When the reconstruction parameters were carefully selected, similar values for noise (~0.15), spatial resolution (~1 cm) and RCs were found, irrespective of the reconstruction algorithm. Analogue results were found in patients. Conclusions Accurate activity quantification is possible when imaging 177 Lu with StarGuide™. However, the impact of septal penetration requires further investigations. GE-OSEM is a valid alternative to the recommended Q.Clear reconstruction algorithm, featuring comparable performances assessed on phantoms and patients.
23
Phase 3 Trial of <sup>177</sup> Lu-Dotatate for Midgut Neuroendocrine Tumors
Jonathan Strosberg, Ghassan El‐Haddad, Edward M. Wolin et al. · New England Journal of Medicine · 2017 · 3.2K citations · Full text
Medicine, Oncology, Pharmacology +17
Lutetium-177–PSMA-617 for Metastatic Castration-Resistant Prostate Cancer
Oliver Sartor, Johann S. de Bono, Kim N. et al. · New England Journal of Medicine · 2021 · 2.6K citations · Full text
Étienne Garin, Lambros Tselikas, Boris Guiu et al. · The Lancet. Gastroenterology & hepatology · 2020 · 604 citations
John Violet, Price Jackson, Justin Ferdinandus et al. · Journal of Nuclear Medicine · 2018 · 486 citations · Full text
Medicine, Nuclear Medicine, Oncology +17