Clinical Chemistry and Laboratory Medicine (CCLM) · 2023 · 11 citations · 14 references
Life SciencesBiochemistryImmunologyMass Spectrometric AnalysisMolecular DiagnosticsProteomicsMass SpectrometryMass Spectrometry-based ProteomicsMultiple MyelomaPeptide AnalysisProtein QuantificationTargeted ProteomicsAssay SpecificityMass Spectrometry ProteomicsPeptide Mass SpectrometryProtein Biomarker QuantificationSerum BiomarkersSerum SamplingTargeted Mass SpectrometryTargeted Mass Spectrometry Analysis
OBJECTIVES: Minimal residual disease status in multiple myeloma is an important prognostic biomarker. Recently, personalized blood-based targeted mass spectrometry (MS-MRD) was shown to provide a sensitive and minimally invasive alternative to measure minimal residual disease. However, quantification of MS-MRD requires a unique calibrator for each patient. The use of patient-specific stable isotope labelled (SIL) peptides is relatively costly and time-consuming, thus hindering clinical implementation. Here, we introduce a simplification of MS-MRD by using an off-the-shelf calibrator. METHODS: SILuMAB-based MS-MRD was performed by spiking a monoclonal stable isotope labeled IgG, SILuMAB-K1, in the patient serum. The abundance of both M-protein-specific peptides and SILuMAB-specific peptides were monitored by mass spectrometry. The relative ratio between M-protein peptides and SILuMAB peptides allowed for M-protein quantification. We assessed linearity, sensitivity and reproducibility of SILuMAB-based MS-MRD in longitudinally collected sera from the IFM-2009 clinical trial. RESULTS: >0.985). Additionally, signal intensity of spiked SILuMAB can be used for quality control purpose to assess system performance and incomplete SILuMAB digestion can be used as quality control for sample preparation. CONCLUSIONS: Compared to SIL peptides, SILuMAB-based MS-MRD improves the reproducibility, turn-around-times and cost-efficacy of MS-MRD without diminishing its sensitivity and specificity. Furthermore, SILuMAB can be used as a MS-MRD quality control tool to monitor sample preparation efficacy and assay performance.
14
Selected reaction monitoring for quantitative proteomics: a tutorial
Vinzenz Lange, Paola Picotti, Bruno Domon et al. · Molecular Systems Biology · 2008 · 1.4K citations · Full text
Lenalidomide, Bortezomib, and Dexamethasone with Transplantation for Myeloma
Michel Attal, Valérie Lauwers‐Cancès, Cyrille Hulin et al. · New England Journal of Medicine · 2017 · 1.2K citations · Full text
Medicine, Oncology, Pharmacotherapy +17
Katherine A. Turner, Jody L. Frinack, Michael Ettore et al. · Clinical Chemistry and Laboratory Medicine (CCLM) · 2020 · 68 citations · Full text
Joannes F.M. Jacobs, Katherine A. Turner, Maria Stella Graziani et al. · Clinical Chemistry and Laboratory Medicine (CCLM) · 2020 · 65 citations · Full text