Radiographics · 2023 · 17 citations · 13 references
MedicineOncologyRadiologyDiagnostic ImagingDiagnostic RadiologyImage InterpretationBreast Cancer ImagingBreast ExaminationBreast ImagingBreast Lesion CharacterizationMammography PhysicsContrastContrast EnhancementImage Artefacts In MammographyMammographic Image QualityMammographyMammography ImagingParenchymal Enhancement PatternsSignal-to-background Enhancement
Contrast-enhanced mammography (CEM) involves addition of intravenous iodinated contrast material at digital mammography, thus increasing the ability to detect breast cancer owing to tumor contrast enhancement. After image acquisition, interpretation includes careful assessment of the technique, artifacts, and pitfalls and reporting with a standard lexicon category and appropriate follow-up recommendations. Artifacts and pitfalls that may cause image misinterpretation should be detected and distinguished from pathologic conditions. Different artifacts apparent on CEM images are usually caused during image acquisition and include CEM-specific and contrast agent–related artifacts, apart from the typical digital mammography artifacts. The pitfalls are related to technical and diagnostic difficulties. One disadvantage of CEM that MRI does not have is a technical factor related to a mammography technique that consists of blind spots that may not be included in the imaging field of mammography views, including the axilla, medial region of the breast, or areas close to the breast wall. Normal breast tissue enhancement called background parenchymal enhancement is also present at CEM and may affect interpretation performance. Diagnostic pitfalls are caused by minimally enhancing lesions, such as invasive lobular carcinomas and mucinous carcinomas, which are difficult to detect with CEM, resulting in false-negative findings. Benign lesions can show enhancement at CEM and represent false-positive lesions that should also be recognized. The authors discuss image interpretation of CEM studies and focus on the artifacts and pitfalls that may be encountered.
13
Maxine S. Jochelson, D. David Dershaw, Janice S. Sung et al. · Radiology · 2012 · 420 citations · Full text
Dual-Energy Contrast-enhanced Digital Subtraction Mammography: Feasibility
John Lewin, Pamela K. Isaacs, Virginia Vance et al. · Radiology · 2003 · 384 citations
Improved imaging of the augmented breast
G W Eklund, RC Busby, SH Miller et al. · American Journal of Roentgenology · 1988 · 257 citations
Ulrich Lalji, Ivo Houben, Renate Prevos et al. · European Radiology · 2016 · 133 citations · Full text