JACC: Cardiovascular Interventions · 2023 · 29 citations · 9 references
MedicineCardiologySurgeryClinical CardiologyInterventional CardiologyVascular SurgeryArterial InterventionsBalloon AngioplastyCoronary AngioplastyCoronary Artery DiseaseIschemic Heart DiseaseNonvascular InterventionsCoronary Balloon AngioplastyEndovascular Treatment SelectionFemoropopliteal DiseaseFemoropopliteal InterventionFemoropopliteal RevascularizationPeripheral AngioplastyPeripheral Balloon AngioplastyVascular Stenting
BACKGROUND: Randomized trials have shown comparable outcomes between second-generation low-dose drug-coated balloons (LD-DCBs) and first-generation high-dose drug-coated balloons (HD-DCBs); but the trial patients had low clinical complexity, and there were no comparisons in medically complex populations. OBJECTIVES: ) in patients with symptomatic femoropopliteal artery disease. METHODS: PROSPECT MONSTER (Prospective Comparison of Second-Generation Low-Dose Drug-Coated Balloon With High-Dose Drug-Coated Balloon) was a prospective, multicenter, nonrandomized trial that prospectively collected data from 581 patients who underwent endovascular therapy with the LD-DCB (n = 370) or the HD-DCB (n = 211) for symptomatic femoropopliteal artery disease (Rutherford classes 2-5). The primary outcome was the 1-year primary patency of the LD-DCB in comparison with that of the HD-DCB, as evaluated using propensity score matching. The incidence of impaired flow after drug-coated balloon application was also evaluated. RESULTS: Propensity score matching extracted 163 pairs (358 and 163 patients in the LD-DCB and HD-DCB groups, respectively), with no significant intergroup difference in baseline characteristics. The 1-year primary patency rates in the matched population were similar between the LD-DCB and HD-DCB groups (87.0% [95% CI: 82.5%-91.7%] vs 81.3% [95% CI: 74.8%-88.5%]; HR: 0.93; 95% CI: 0.55-1.59; P = 0.79), as was the incidence of impaired flow (13.6% vs 9.8%; OR: 1.46; 95% CI: 0.78-2.73; P = 0.24). No baseline characteristics had any significant interaction effects on the association of the LD-DCB vs the HD-DCB and 1-year restenosis risk. CONCLUSIONS: LD-DCBs demonstrate efficacy and safety comparable with HD-DCBs in patients with complex clinical backgrounds, suggesting that drug-coated balloon treatment using a lower dose may be possible.
9
Victor Aboyans, Jean‐Baptiste Ricco, Marie-Louise Bartelink et al. · European Heart Journal · 2017 · 3.3K citations · Full text
Medicine, Cardiology, Surgery +17
Trial of a Paclitaxel-Coated Balloon for Femoropopliteal Artery Disease
Kenneth Rosenfield, Michael R. Jaff, Christopher J. White et al. · New England Journal of Medicine · 2015 · 671 citations
Medicine, Cardiology, Surgery +16
Sabine Steiner, Andrej Schmidt, Thomas Zeller et al. · European Heart Journal · 2020 · 71 citations · Full text