JGH Open · 2023 · 10 citations · 34 references
Veterinary MedicineCardiologyInternal MedicineDiagnostic ImagingUltrasonographyUltrasoundCardiac UltrasonographyChronic Liver DiseaseDiagnostic UltrasonographyElastographyLiver DiseaseLiver ImagingLiver ElastographyLiver UltrasoundMedian AgeShear Wave ImagingStiffness MeasurementTissue Stiffness MeasurementTwo-dimensional Shear Wave ElastographyUltrasonography Of The Liver
Abstract Background and Aims Fontan‐associated liver disease (FALD) is a long‐term complication of the Fontan procedure. Guidelines recommend elastography, but the utility of transient elastography (TE) and two‐dimensional shear wave elastography (2D SWE) is unknown. We aimed to evaluate the relationship between TE and 2D SWE in FALD. Methods This prospective cohort study included 25 patients managed in a specialist clinic between January 2018 and August 2021. Trained clinicians performed 2D SWE (GE Logiq‐E9) and TE (FibroScan 503 Touch) on the same day under the same conditions. Laboratory, echocardiography, and imaging data were collected. The atrioventricular systolic‐to‐diastolic duration (AVV S/D ratio) was calculated as a measure of cardiac diastolic function. Results We analyzed 40 paired measurements. Median age was 22 years. Median liver stiffness measurement (LSM) was 15.4 kPa (12.1–19.6) by TE and 8.0 kPa (7.0–10.3) ( P = 0.001) by 2D SWE. There was weak correlation between the modalities ( r = 0.41, P = 0.004). There was no correlation between time since Fontan and LSM by TE ( r = 0.15, P = 0.19) or 2D SWE ( r = 0.19, P = 0.13). There was no difference in LSM irrespective of whether sonographic cirrhosis was present or absent by TE (17.4 kPa [15.9–23.6] vs. 14.9 kPa [12.0–19.4], respectively, P = 0.6) or 2D SWE (9.0 kPa [2.8–10.5] vs. 8.0 kPa [6.7–10.1], P = 0.46). There was no correlation between AVV S/D ratio and LSM by TE ( r = 0.16, P = 0.18) or 2D SWE ( r = 0.02, P = 0.45). Conclusions In FALD, TE and 2D SWE are poorly correlated. LSM by either modality was not associated with known risk factors for liver fibrosis or Fontan function. Based on these data, the role of elastography in FALD is uncertain.
34
Roberto M. Lang, Luigi P. Badano, Victor Mor‐Avi et al. · Journal of the American Society of Echocardiography · 2015 · 18K citations · Full text
Lawrence Rudski, Wyman W. Lai, Jonathan Afilalo et al. · Journal of the American Society of Echocardiography · 2010 · 7K citations · Full text
William A. Zoghbi, Maurice Enriquez‐Sarano, Elyse Foster et al. · Journal of the American Society of Echocardiography · 2003 · 4.1K citations · Full text
Medicine, Cardiology, Surgery +14