ACS Sensors · 2023 · 17 citations · 39 references
EngineeringBioengineeringBiotechnologyBiosensorsNanobiotechnologySensorsBiological SensorsElectrochemical BiosensorsEnzymatic BiosensorsEnzyme-based BiosensorsNanomaterial-based BiosensorsNanosensorsBiochemical SensingCancer DiagnosticsElectron TunnelingPhotocurrent GenerationTelomerase Activity AssessmentTelomerase EnzymeTelomerase Reverse TranscriptaseUltrasensitive Detection
Telomerase, as a specialized reverse transcriptase, plays a vital role in early cancer diagnostics and prognosis; thus, developing efficient sensing technologies is of vital importance. Herein, an innovative “signal-on–off” photoelectrochemical (PEC) sensing platform was developed for ultrasensitive evaluation of telomerase activity based on an electron-transfer tunneling distance regulation strategy and DNAzyme-triggerable biocatalytic precipitation. Concretely, cascade internal electric fields between CuInS 2 quantum dots (QDs), graphitic carbon nitride nanosheets (g-C 3 N 4 NSs), and TiO 2 nanorod arrays (NRAs) were developed to realize cascade electron extraction and hole transfer. Enabled by such a design, an effective “signal-on” state to gain a progressively enhanced PEC output was designed by suppressing the photogenerated electron–hole pair recombination. With the introduction of hairpin probe H2 and the subsequent extension of the primer sequence driven by the target telomerase, the CuInS 2 QDs labeled with hairpin probe H1 were programmatically unfolded, resulting in CuInS 2 QDs’ close proximity to the working electrode away from the cascade interface, accompanied by the formation of G-quadruplex/hemin complexes. The gradual undermining of tunneling distance and implantation of DNAzyme-initiating biocatalytic precipitation tremendously induced the sluggish migration kinetics of the photoinduced charge, accompanied by the photocurrent intensity decrement, leading to the “signal-off” state. Under optimized conditions, the as-prepared PEC biosensor realizes ultrasensitive detection of telomerase activity from 10 to 10 5 cell·mL –1 with a detection limitation of 3 cells·mL –1 . As a proof of concept, this well-designed method provides new insights into signal amplification for telomerase activity evaluation and also presents promising potential for further development in drug screening, healthcare diagnostics, and biological assays.
39
Unique S-scheme heterojunctions in self-assembled TiO2/CsPbBr3 hybrids for CO2 photoreduction
Feiyan Xu, Kai Meng, Cheng Bei et al. · Nature Communications · 2020 · 1.4K citations · Full text
Yang Wang, Xueqin Liu, Jia Liu et al. · Angewandte Chemie International Edition · 2018 · 490 citations
Natural Sciences, Materials Engineering, Materials Science +17
S-scheme heterojunction photocatalysts for CO2 reduction
Linxi Wang, Bicheng Zhu, Jianjun Zhang et al. · Matter · 2022 · 416 citations