Cardiovascular Engineering and Technology · 2023 · 15 citations · 34 references
EngineeringBioengineeringBiomedical EngineeringComputational Fluid DynamicsDiagnostic ImagingFluid DynamicsAneurysm SurgeryCerebral Blood FlowHemodynamicsHemodynamics ModelingMedical Image AnalysisSubarachnoid HemorrhageAneurysmal FlowBlood FlowFlow DistributionFlow SplittingIntracranial HemodynamicsShear StressTime-dependent Flow AnalysisWall Shear Stress
PURPOSE: Image-based blood flow simulations are increasingly used to investigate the hemodynamics in intracranial aneurysms (IAs). However, a strong variability in segmentation approaches as well as the absence of individualized boundary conditions (BCs) influence the quality of these simulation results leading to imprecision and decreased reliability. This study aims to analyze these influences on relevant hemodynamic parameters within IAs. METHODS: As a follow-up study of an international multiple aneurysms challenge, the segmentation results of five IAs differing in size and location were investigated. Specifically, five possible outlet BCs were considered in each of the IAs. These are comprised of the zero-pressure condition (BC1), a flow distribution based on Murray's law with the exponents n = 2 (BC2) and n = 3 (BC3) as well as two advanced flow-splitting models considering the real vessels by including circular cross sections (BC4) or anatomical cross sections (BC5), respectively. In total, 120 time-dependent blood flow simulations were analyzed qualitatively and quantitatively, focusing on five representative intra-aneurysmal flow and five shear parameters such as vorticity and wall shear stress. RESULTS: The outlet BC variation revealed substantial differences. Higher shear stresses (up to Δ9.69 Pa), intrasaccular velocities (up to Δ0.15 m/s) and vorticities (up to Δ629.22 1/s) were detected when advanced flow-splitting was applied compared to the widely used zero-pressure BC. The tendency of outlets BCs to over- or underestimate hemodynamic parameters is consistent across different segmentations of a single aneurysm model. Segmentation-induced variability reaches Δ19.58 Pa, Δ0.42 m/s and Δ957.27 1/s, respectively. Excluding low fidelity segmentations, however, (a) reduces the deviation drastically (>43%) and (b) leads to a lower impact of the outlet BC on hemodynamic predictions. CONCLUSION: With a more realistic lumen segmentation, the influence of the BC on the resulting hemodynamics is decreased. A realistic lumen segmentation can be ensured, e.g., by using high-resolved 2D images. Furthermore, the selection of an advanced outflow-splitting model is advised and the use of a zero-pressure BC and BC based on Murray's law with exponent n = 3 should be avoided.
34
Hemodynamic–Morphologic Discriminants for Intracranial Aneurysm Rupture
Jianping Xiang, Sabareesh K. Natarajan, Markus Tremmel et al. · Stroke · 2010 · 767 citations · Full text
Medicine, Neurosurgery, Surgery +17
Association of Hemodynamic Characteristics and Cerebral Aneurysm Rupture
Juan R. Cebral, Fernando Mut, J. Weir et al. · American Journal of Neuroradiology · 2010 · 455 citations
Kristian Valen‐Sendstad, David A. Steinman · American Journal of Neuroradiology · 2013 · 168 citations · Full text
Natural Sciences, Neurosurgery, Computational Fluid Dynamics +16