Circulation Cardiovascular Interventions · 2023 · 75 citations · 22 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologyVascular SurgeryCardiac Valve SurgeryTranscatheter Valve TherapyTricuspid RegurgitationTricuspid Valve DiseaseComparative Clinical EffectivenessEchocardiographic Severity AssessmentEdge-to-edge Tricuspid RepairEdge-to-edge Valve RepairMulticenter TrialsPrimary Tricuspid RegurgitationTranscatheter Edge-to-edge RepairTranscatheter Repair
BACKGROUND: Tricuspid regurgitation (TR) is a common and progressive valve disease with significant mortality and hospitalization burden. Tricuspid transcatheter edge-to-edge repair provides a treatment option for high-risk patients with primary and secondary TR. METHODS: The TRILUMINATE trial ([Trial to Evaluate Treatment With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater Tricuspid Regurgitation]; n=85) is an international, prospective, single-arm, multicenter study to investigate the safety and performance of tricuspid transcatheter edge-to-edge repair with the TriClip implant in patients with symptomatic moderate or greater TR. Echocardiographic assessment was performed at a core laboratory. Outcomes included safety and clinical effectiveness and echocardiographic assessment of TR. RESULTS: At 2 years, TR was reduced to moderate or less in 60% of subjects, and reduction of at least 1 grade was achieved in 85.4% of subjects. TR reduction was sustained in 75% of the patients. While most metrics suggest the majority of favorable remodeling occurred within the first 30 days post-procedure, both right ventricular end diastolic diameter and tricuspid annular plane systolic excursion show signals of continued favorable remodeling through 2 years. Substantial improvements in 6-minute walking distance, New York Heart Association functional class, and Kansas City Cardiomyopathy Questionnaire score were sustained from 30 days to 2 years. Even with low rates of cardiovascular mortality (15.3%) and all-cause mortality (18.7%) noted at 2 years, all-cause hospitalization rate decreased from 1.30 events per patient-year 1 year before device implantation to 0.66 events per patient-year 2 years after the TriClip procedure, representing a reduction of 49% ( P <0.0001). CONCLUSIONS: Tricuspid transcatheter edge-to-edge repair using the TriClip implant was found to be safe and effective, with sustained benefits at 2 years in subjects with symptomatic moderate or greater TR. Repair efficacy was durable at 2 years in 75% of the patients. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03227757.
22
Transcatheter Repair for Patients with Tricuspid Regurgitation
Paul Sorajja, Brian Whisenant, Nadira Hamid et al. · New England Journal of Medicine · 2023 · 855 citations
Medicine, Cardiology, Surgery +16
Clinical Outcome of Isolated Tricuspid Regurgitation
Yan Topilsky, Vuyisile T. Nkomo, Ori Vatury et al. · JACC. Cardiovascular imaging · 2014 · 632 citations