MedicineCardiologyCardiothoracic SurgeryHemodynamic ManagementInterventional CardiologyAtrial ElectrophysiologyAtrial FibrillationClinical TrialsHeart FailureLeft Atrial Appendage ClosureAmplatzer Amulet DeviceLeft Atrial Appendage MorphologyLeft Atrial Appendage Occlusion DevicesPercutaneous Left Atrial Appendage ClosurePostprocedural Follow-up
BACKGROUND: The Amulet (Abbott) left atrial appendage occluder investigational device exemption trial is the largest randomized trial evaluating the safety and effectiveness of the Amulet left atrial appendage occluder compared with the Watchman 2.5 device (Boston Scientific) through 5 years. OBJECTIVES: This analysis evaluated the device effect on 3-year outcomes in the Amulet investigational device exemption trial. METHODS: The medication regimen and key clinical outcomes were reported through 3 years including: 1) the composite of ischemic stroke or systemic embolism (SE); 2) the composite of all strokes, SE, or cardiovascular (CV) death; 3) major bleeding; and 4) all-cause death and CV death. RESULTS: A total of 1,878 patients at 108 sites were randomized. A significantly higher percentage of patients were free of oral anticoagulation usage at 3 years with Amulet (96.2%) vs Watchman (92.5%) (P < 0.01). Clinical outcomes were comparable for the composite of ischemic stroke or SE (5.0% vs 4.6%; P = 0.69); the composite of all strokes, SE, or CV death (11.1% vs 12.7%; P = 0.31); major bleeding (16.1% vs 14.7%; P = 0.46); all-cause death (14.6% vs 17.9%; P = 0.08); and CV death (6.6% vs 8.5%; P = 0.14) for Amulet and Watchman, respectively. Through 3 years, device factors (device-related thrombus or peridevice leak ≥3 mm) preceded ischemic stroke events and CV deaths more frequently in Watchman compared with Amulet patients. CONCLUSIONS: The Amulet occluder demonstrated continued safety and effectiveness with over 96% free of oral anticoagulation usage through 3 years in a high-risk population compared to the Watchman device. (AMPLATZER Amulet LAA Occluder Trial [Amulet IDE]; NCT02879448).
17
Standardized Bleeding Definitions for Cardiovascular Clinical Trials
Roxana Mehran, Sunil V. Rao, Deepak L. Bhatt et al. · Circulation · 2011 · 4.4K citations
Medicine, Cardiology, Hematology +10
Leif Friberg, Mårten Rosenqvist, Gregory Y.H. Lip · European Heart Journal · 2012 · 1.2K citations · Full text
5-Year Outcomes After Left Atrial Appendage Closure
Vivek Y. Reddy, Shephal K. Doshi, Saibal Kar et al. · Journal of the American College of Cardiology · 2017 · 991 citations · Full text
Stefan H. Hohnloser, Dimitri Pajitnev, Janice Pogue et al. · Journal of the American College of Cardiology · 2007 · 462 citations
Device-Related Thrombus After Left Atrial Appendage Closure
Srinivas R. Dukkipati, Saibal Kar, David R. Holmes et al. · Circulation · 2018 · 437 citations · Full text