Diabetes Technology & Therapeutics · 2023 · 32 citations · 17 references
MedicineClinical PharmacyInternal MedicineDiabetologyDrug DeliveryBlood Glucose MonitoringContinuous Glucose MonitoringDiabetes MellitusGlycemic ControlGlycemic MonitoringInsulin TherapyGlucose MonitoringGlucose Monitoring DevicesGlycemic TargetsInsulin Delivery DevicesInsulin ManagementInsulin Therapy MonitoringIntravenous Insulin TherapyTelemedicine In Diabetes Care
Introduction: Multiple daily injection insulin therapy frequently fails to meet hospital glycemic goals and is prone to hypoglycemia. Automated insulin delivery (AID) with remote glucose monitoring offers a solution to these shortcomings. Research Design and Methods: In a single-arm multicenter pilot trial, we tested the feasibility, safety, and effectiveness of the Omnipod 5 AID System with real-time continuous glucose monitoring (CGM) for up to 10 days in hospitalized patients with insulin-requiring diabetes on nonintensive care unit medical–surgical units. Primary endpoints included the proportion of time in automated mode and percent time-in-range (TIR 70–180 mg/dL) among participants with >48 h of CGM data. Safety endpoints included incidence of severe hypoglycemia and diabetes-related ketoacidosis (DKA). Additional glycemic endpoints, CGM accuracy, and patient satisfaction were also explored. Results: Twenty-two participants were enrolled; 18 used the system for a total of 96 days (mean 5.3 ± 3.1 days per patient), and 16 had sufficient CGM data required for analysis. Median percent time in automated mode was 95% (interquartile range 92%–98%) for the 18 system users, and the 16 participants with >48 h of CGM data achieved an overall TIR of 68% ± 16%, with 0.17% ± 0.3% time <70 mg/dL and 0.06% ± 0.2% time <54 mg/dL. Sensor mean glucose was 167 ± 21 mg/dL. There were no DKA or severe hypoglycemic events. All participants reported satisfaction with the system at study end. Conclusions: The use of AID with a disposable tubeless patch-pump along with remote real-time CGM is feasible in the hospital setting. These results warrant further investigation in randomized trials.
17
Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose
William L. Clarke, Daniel J. Cox, Linda Gonder‐Frederick et al. · Diabetes Care · 1987 · 1.4K citations
Medicine, Endocrinology, Biosensors +16
Guillermo E. Umpierrez, Richard Hellman, Mary T. Korytkowski et al. · The Journal of Clinical Endocrinology & Metabolism · 2012 · 1.1K citations · Full text
Closed-Loop Insulin Delivery for Glycemic Control in Noncritical Care
Lia Bally, Hood Thabit, Sara Hartnell et al. · New England Journal of Medicine · 2018 · 220 citations · Full text