The effect of the corona wire distribution with W-type of collecting plates on the characteristics of electrostatic precipitators

Mo’ath Bani Fayyad, Angel Asipuela, Tamás Iváncsy

Journal of Electrostatics · 2023 · 16 citations · 34 references

DOIFull text

Open access

Concepts

Abstract

Electrostatic precipitators (ESPs) are commonly applied to eliminate particles in various industrial sectors. A numerical study is conducted to evaluate the use of different arrangements of W-type collecting plates compared to flat plates (FPs) for a single stage of ESP. The modeling was done for six different ESP cases, and the W-type results obtained are compared to FPs to determine the consequence of corona wires spacing at different ratios of Lww/Lwp (Lww is a wire–wire space and Lwp is a wire–plate space) on the distribution especially of the electrical field, space charge density, and particle collection. The electric field close to the grounded collecting plates continued to rise when Lww/Lwp is reduced for both shapes. Furthermore, when compared to FPs, the use of W-types improves particle collection efficiency.

References

34