EngineeringBiomedical EngineeringComputer EngineeringBiomedical Signal ProcessingEmbedded SystemsSensorsBiomedical InstrumentationBiomedical SensorsIot SensorsWearable BiosensorsWearable Health TechnologiesWearable Internet Of ThingsBiosignal AcquisitionBiosignal ProcessingEnergy-efficient ProcessingInternet Of Things ApplicationsUltra-low-power CmosWearable Health MonitoringWearable Medical DevicesWearable Physiological Sensors
Wearable biosignal processing applications are driving significant progress toward miniaturized, energy-efficient Internet-of- Things solutions for both clinical and consumer applications. However, scaling toward high-density multi-channel front-ends is only feasible by performing data processing and machine Learning (ML) near-sensor through energy-efficient edge processing. To tackle these challenges, we introduce BioGAP, a novel, compact, modular, and lightweight (6g) medical-grade biosignal acquisition and processing platform powered by GAP9, a ten-core ultra-low-power SoC designed for efficient multi-precision (from FP to aggressively quantized integer) processing, as required for advanced ML and DSP. BioGAP's form factor is 16x21x14 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> and comprises two stacked PCBs: a baseboard integrating the GAP9 SoC, a wireless Bluetooth Low Energy (BLE) capable SoC, a power management circuit, and an accelerometer; and a shield including an analog front-end (AFE) for ExG acquisition. Finally, the system also includes a flexibly placeable photoplethysmogram (PPG) PCB with a size of 9x7x3 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> and a rechargeable battery ( <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\phi$</tex> 12x5 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ), We demonstrate BioGAP on a Steady State Visually Evoked Potential (SSVEP)-based Brain-Computer Interface (BCI) application. We achieve 3.6 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mu J/sample$</tex> in streaming and 2.2 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mu J/sample$</tex> in onboard processing mode, thanks to an efficiency on the FFT computation task of 16.7 Mflops/s/mW with wireless bandwidth reduction of 97%, within a power budget of just 18.2 mW allowing for an operation time of 15 h.
9
Hideyuki Ando, Kenji Takizawa, Takeshi Yoshida et al. · IEEE Transactions on Biomedical Circuits and Systems · 2016 · 94 citations
Engineering, Biomedical Engineering, Electrical Engineering +17
Epileptic seizure onset detection based on EEG and ECG data fusion
Marwa Qaraqe, Muhammad Ismail, Erchin Serpedin et al. · Epilepsy & Behavior · 2016 · 51 citations
Medicine, Neurology, Neuroscience +14