Respiratory Care · 2023 · 10 citations · 33 references
MedicinePhysiologyRehabilitation MedicineExercise PhysiologyExercise TestingPulmonary RehabilitationAerobic ExerciseCardiopulmonary Exercise TestingCardiorespiratory FitnessDyspnea ManagementExercise Pulmonary Function TestingExercise Tolerance AssessmentDyspnea MeasurementDyspnea ReductionExercise DyspneaExercise EnduranceExercise-induced DesaturationExertional Dyspnea AssessmentHigh-flow Nasal Cannula Oxygen TherapyOxygenation Status
BACKGROUND: Exercise-induced O 2 desaturation contributes to dyspnea and exercise intolerance in various respiratory diseases. This study assessed whether automated O 2 titration was superior to fixed-flow O 2 to improve exertional dyspnea and walking exercise endurance. We also aimed at evaluating possible additive effects of high-flow nasal cannula coupled with automated O 2 titration on these outcomes. METHODS: Subjects with chronic respiratory diseases and exercise-induced desaturation performed a 3-min constant-speed shuttle test (CSST) and an endurance shuttle walking test (ESWT) with either (1) fixed-flow O 2 , (2) automated O 2 titration targeting an S pO 2 of 94% (± 2%), and (3) automated O 2 titration + high-flow nasal cannula according to a randomized sequence. The main outcome was Borg dyspnea score at the end of the 3-min CSST. Secondary outcomes included endurance time and dyspnea during ESWT and oxygenation status during exercise. RESULTS: Ten subjects with COPD, 10 with interstitial lung disease, 5 with pulmonary hypertension, and 3 with cystic fibrosis completed the study. Compared to fixed-flow O 2 , automated O 2 titration did not reduce dyspnea at the end of the 3-min CSST. Endurance time during the ESWT was prolonged with automated O 2 titration (mean difference 298 [95% CI 205–391] s, P < .001), and dyspnea at isotime was reduced. No further improvement was noted when high-flow nasal cannula was added to automated O 2 titration. Compared to fixed-flow O 2 , O 2 flows were higher with automated O 2 titration, resulting in better oxygenation. CONCLUSIONS: Automated O 2 titration was superior to fixed-flow O 2 to alleviate dyspnea and improve exercise endurance during the ESWT in subjects with a variety of chronic respiratory diseases. Adding high-flow nasal cannula to automated O 2 titration provided no further benefits.
33
Psychophysical bases of perceived exertion
Gunnar Borg · Medicine & Science in Sports & Exercise · 1982 · 16.4K citations
Research in high flow therapy: Mechanisms of action
Kevin Dysart, Thomas L. Miller, Marla R. Wolfson et al. · Respiratory Medicine · 2009 · 735 citations