IEEE Transactions on Power Electronics · 2023 · 291 citations · 8 references
EngineeringElectrical EngineeringElectric MachinesInstrumentationPower ElectronicsElectromagnetic Torque ProductionMachine TestingMagnetic Circuit AnalysisPermanent Magnet MachinesSynchronous MachinesInterior Permanent Magnet Synchronous MachinesPermanent Magnet MotorsPermanent Magnet Synchronous MotorsReluctance MotorsSynchronous MotorsSynchronous Reluctance MachinesSynchronous Reluctance MotorsTest Bench Calibration
In order to improve the efficiency, interior permanent magnet synchronous motors (IPMSMs) or the synchronous reluctance motors (SynRMs) need to be calibrated to obtain the maximum torque per ampere (MTPA) and flux-weakening (FW) curves. In industrial application, there are different types of IPMSMs and SynRMs. It is expensive and time-consuming to build test benches to calibrate each motor. In this letter, a physics-informed network is proposed to obtain the MTPA and FW operating curves. Only data from accelerating experiment, when motor operates without load, are adopted. The test bench is unnecessary. Experimental results show the validity of proposed method.
8
Ludovico Ortombina, Fabio Tinazzi, M. Zigliotto · IEEE Transactions on Industrial Electronics · 2017 · 86 citations · Full text
Zisui Zhang, Chenchen Wang, Minglei Zhou et al. · IEEE Journal of Emerging and Selected Topics in Power Electronics · 2018 · 75 citations