An electrochemical Cr(III)-Selective Sensor-Based on a Newly Synthesized Ligand and Optimization of Electrode With a Nano Particle

Mohammad Hossein Fekri, Hamid Khanmohammadi, M. Darvishpour

International Journal of Electrochemical Science · 2011 · 22 citations · 19 references

DOIFull text

Open access

Concepts

Abstract

A novel ion-selective poly(vinyl chloride) membrane sensor for Cr(III) ions based on a crown ether as a new ionophore has been prepared and studied.The electrode exhibits a good potentiometric response for Cr(III), response time ≤ 15 s, over a wide concentration range 1.0 × 10-5 to 1.0 × 10-1 M with a slope 20.4 ± 0.5 mV/decade and low detection limit of 8.9 × 10-6 M. The best performance was observed with the membrane having the PVC-ligand-acetophenone-oleic acid-TiO2 nano particle composition 5:1:7:1:1.