Medical Physics · 2023 · 44 citations · 47 references
MedicineRadiation OncologyOptimizationRadiation DosimetryTreatment PlanningPatient Dose OptimizationPatient-specific DosimetryPlan OptimizationRadiation TherapyRadiation Treatment PlanningThree-dimensional Dose DistributionConvex RelaxationsDose PlanningOptimization Objective EvaluationOrgan-at-risk ConstraintsPerformance ObjectivesRadiotherapy Dose PlanningTreatment Plan OptimizationTreatment Planning Optimization
BACKGROUND: LATTICE radiation therapy delivers 3D heterogenous dose of high peak-to-valley dose ratio (PVDR) to the tumor target, with peak dose at lattice vertices inside the target and valley dose for the rest of the target. Although the lattice vertex positions can impact PVDR inside the target and sparing of organs-at-risk (OAR), they are fixed as constants and not optimized during treatment planning in current clinical practice. PURPOSE: This work proposes a new LATTICE plan optimization method that can optimize lattice vertex positions during LATTICE treatment planning, which is the first lattice position optimization study to the best of our knowledge. METHODS: The new LATTICE treatment planning method optimizes lattice vertex positions as well as other plan variables (e.g., photon fluences or proton spot weights), with optimization objectives for target PVDR and OAR sparing. To satisfy mathematical differentiability, the lattice vertices are approximated in sigmoid functions. For geometric feasibility, proper geometry constraints are enforced onto lattice vertex positions. The lattice position optimization problem is solved by iterative convex relaxation (ICR) method and alternating direction method of multipliers (ADMM), and lattice vertex positions and photon/proton plan variables are jointly updated via the Quasi-Newton method. RESULTS: Both photon and proton LATTICE RT were considered, and the optimal lattice vertex positions in terms of plan objectives were found by solving all possible combinations on given discrete positions via exhaustive searching based on standard IMRT/IMPT, which served as the ground truth for validating the new LATTICE method. The results show that the new method indeed provided the optimal lattice vertex positions with the smallest optimization objective, the largest target PVDR, and the best OAR sparing. CONCLUSIONS: A new LATTICE treatment planning method is proposed and validated that can optimize lattice vertex positions as well as other photon or proton plan variables for improving target PVDR and OAR sparing.
47
The Split Bregman Method for L1-Regularized Problems
Tom Goldstein, Stanley Osher · SIAM Journal on Imaging Sciences · 2009 · 4.3K citations
Direct aperture optimization: A turnkey solution for step‐and‐shoot IMRT
David Shepard, Matthew A. Earl, X. A. Li et al. · Medical Physics · 2002 · 366 citations
Development of the open-source dose calculation and optimization toolkit matRad
Hans‐Peter Wieser, Eduardo Cisternas, Niklas Wahl et al. · Medical Physics · 2017 · 317 citations · Full text