Ophthalmology Glaucoma · 2023 · 25 citations · 33 references
Health ProfessionsOphthalmologySurgeryOcular AnatomyOcular ImagingOphthalmic SurgeryAqueous Humor PathwaysIntraocular Pressure MeasurementTrabecular MeshworkAqueous Humor Drainage PathwaysAqueous Humor Outflow SurgeryConventional Outflow FacilityConventional Outflow PathwayIndocyanine Green ImagingTrabecular ArchitectureTrabecular Meshwork AnatomyTrabecular Meshwork Outflow
PURPOSE: To investigate the impact of trabecular bypass surgery targeted to angiographically determined high- vs. low-aqueous humor outflow areas on outflow facility (C) and intraocular pressure (IOP). DESIGN: Ex vivo comparative study. SUBJECTS: Postmortem ex vivo porcine and human eyes. METHODS: Porcine (n = 14) and human (n = 13) whole globes were acquired. In both species, anterior segments were dissected, mounted onto a perfusion chamber, and perfused using Dulbecco's phosphate buffered solution containing glucose in a constant flow paradigm to achieve a stable baseline. Fluorescein was perfused into the anterior chamber and used to identify baseline segmental high- and low-flow regions of the conventional outflow pathways. The anterior segments were divided into 2 groups, and a 5 mm needle goniotomy was performed in either a high- or low-flow area. Subsequently, C and IOP were quantitatively reassessed and compared between surgery in baseline "high-flow" and "low-flow" region eyes followed by indocyanine green angiography. MAIN OUTCOME MEASURES: Outflow facility. RESULTS: In all eyes, high- and low-flow segments could be identified. Performing a 5-mm goniotomy increased outflow facility to a variable extent depending on baseline flow status. In the porcine high-flow group, C increased from 0.31 ± 0.09 to 0.39 ± 0.09 μL/mmHg/min (P = 0.12). In the porcine low-flow group, C increased from 0.29 ± 0.03 to 0.56 ± 0.10 μL/mmHg/min (P < 0.001). In the human high-flow group, C increased from 0.38 ± 0.20 to 0.41 ± 0.20 μL/mmHg/min (P = 0.02). In the human low-flow group, C increased from 0.25 ± 0.11 to 0.32 ± 0.11 μL/mmHg/min (<0.001). There was statistically significant greater increase in C for eyes where surgery was targeted to baseline low-flow regions in both porcine (0.07 ± 0.09 vs. 0.27 ± 0.13, P = 0.007 μL/mmHg/min, high vs low flow) and human eyes (0.03 ± 0.03 vs. 0.07 ± 0.02, P = 0.03 μL/mmHg/min, high vs. low flow). CONCLUSIONS: Targeting surgery to low-flow areas of the trabecular meshwork yields higher overall facility increase and IOP reduction compared to surgery in high-flow areas. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
33
Further Studies on Facility of Flow Through the Trabecular Meshwork
W. Morton Grant · Archives of Ophthalmology · 1958 · 290 citations
Medicine, Anatomy, Ophthalmology +15
Variations in active outflow along the trabecular outflow pathway
Elliott D.K., Jia Xu, Lihua Gong et al. · Experimental Eye Research · 2016 · 126 citations · Full text