For a decade, two dynamic perfusion concepts have increasingly been tested in several transplant centres worldwide. We undertook the first systematic review and meta-analysis and identified seven published RCTs, including 1,017 patients, evaluating the effect of machine perfusion (hypothermic and normothermic perfusion techniques) compared to static cold storage in liver transplantation. Both perfusion techniques were associated with lower rates of early allograft dysfunction in the first week after liver transplantation. Hypothermic oxygenated perfusion led to a reduction in major complications, lower "re-transplantation" rates and better graft survival. Both perfusion strategies were found to 'likely' reduce overall biliary complications and non-anastomotic biliary strictures. This study provides the highest current evidence on the role of machine perfusion. Outcomes remain limited to a 1-year post-transplant follow-up. Larger cohort studies with longer follow-up and clinical trials comparing the perfusion techniques are required. This is especially relevant to provide clarity and optimise implementation processes further to support the commissioning of this technology worldwide.