Cardiovascular revascularization medicine · 2023 · 16 citations · 15 references
MedicineCardiologyPharmacologyCardiovascular PharmacotherapyDrug DeliveryInterventional CardiologyBalloon AngioplastyCardiovascular Drug SafetyCoronary AngioplastyCoronary Artery DiseaseIschemic Heart DiseasePercutaneous Coronary InterventionCoronary Artery Disease PharmacotherapyCoronary Stent DeploymentCoronary Stent RestenosisIn-stent ThrombosisLocal Drug DeliveryLocal Drug Delivery MechanismsLocal Drug Delivery SystemsStent-assisted Angioplasty
BACKGROUND: Drug-coated balloon (DCB) angioplasty with paclitaxel-eluting devices is an established treatment for coronary in-stent restenosis (ISR). Biolimus A9™ (BA9), a sirolimus analogue with enhanced lipophilicity, may facilitate enhanced local drug delivery into vascular tissue. A novel DCB coated with Biolimus A9™ represents an alternative to traditional paclitaxel- and sirolimus-coated devices. Hence, we sought to investigate the safety and efficacy of this novel DCB in the treatment of coronary ISR. METHODS AND DESIGN: REFORM (NCT04079192) is a prospective, multicenter, single blind, randomized controlled trial comparing the BA9-DCB (Biosensors Europe SA, Morges, Switzerland) to the paclitaxel-coated SeQuent® Please DCB (Braun Melsungen AG, Germany) in the treatment of coronary ISR. A total of 201 patients with coronary artery disease and an indication for interventional treatment of ISR in a bare-metal stent (BMS) or drug-eluting stent (DES) have been randomized 2:1 to receive treatment with the BA9- or the paclitaxel-DCB comparator. Patients were enrolled across 24 investigational centers in Europe and Asia. The primary endpoint is percent diameter stenosis (%DS) of the target segment as assessed by quantitative coronary angiography (QCA) at 6 months. Key secondary endpoints are in-stent late lumen loss, binary restenosis, target lesion failure, target vessel failure, myocardial infarction and death at 6 months. Subjects will be followed for 24 months from enrolment. IMPLICATIONS: The REFORM trial will seek to prove that the BA9-DCB is non-inferior to the standard paclitaxel-DCB comparator in the treatment of coronary ISR with respect to %DS at 6 months and has similar safety characteristics.
15
World Medical Association Declaration of Helsinki
JAMA · 2013 · 29.4K citations
Fourth Universal Definition of Myocardial Infarction (2018)
Kristian Thygesen, Joseph S. Alpert, Allan S. Jaffe et al. · Circulation · 2018 · 3.6K citations · Full text
2018 ESC/EACTS Guidelines on myocardial revascularization
Franz‐Josef Neumann, Miguel Sousa‐Uva, Anders Ahlsson et al. · EuroIntervention · 2019 · 1.3K citations
Robert A. Byrne, Franz–Josef Neumann, Julinda Mehilli et al. · The Lancet · 2012 · 456 citations