Journal of Interventional Cardiac Electrophysiology · 2023 · 21 citations · 27 references
MedicineCardiologyBiomedical ImagingElectrophysiologyInterventional CardiologyAblation TherapyAtrial FibrillationCardiac CatheterizationCatheter AblationIntracardiac ElectrophysiologyAblation SafetyAtrial Activation MappingAtrial MappingPercutaneous AblationPulmonary Vein IsolationPulsed Field AblationSurgical AblationThree-dimensional Electroanatomic Mapping
BACKGROUND: Focal pulsed field ablation (FPFA) is a novel and promising method of cardiac ablation. The aim of this study was to report the feasibility, short-term safety, and procedural findings for a broad spectrum of ablated atrial arrhythmias. METHODS: Patients (n = 51) scheduled for ablation of atrial arrhythmias were prospectively included and underwent FPFA using the Galvanize CENTAURI generator with energy delivery through commercially available ablation catheters with ultrahigh-density (UHDx) 3D electroanatomic voltage/local activation time map evaluations. Workflow, procedural data, and peri-procedural technical errors and complications are described. RESULTS: Planned ablation strategy was achieved with FPFA-only in 48/51 (94%) of the cases. Ablation strategy was first-time pulmonary vein isolation (PVI) in 17/51 (36%), repeat ablation in 18/51 (38%), PVI + in 13/51 (28%), and cavotricuspid isthmus block (CTI)-only in 3/51 (6%). The mean procedure time was 104 ± 31 min (first-time PVI), 114 ± 26 min (repeat procedure), 152 ± 36 min (PVI +), and 62 ± 17 min (CTI). Mean UHDx mapping time to assess lesion formation and block after ablation was 7 ± 4 min with 5485 ± 4809 points. First pass acute (linear) isolation with bidirectional block for anatomical lesion sets was 120/124 (97%) for all PVs, 17/17 (100%) for (any) isthmus, and 14/17 (82%) for left atrium posterior wall (LAPW). We observed several time-consuming integration errors with the used ablation system (mean 3.4 ± 3.7 errors/procedure), one transient inferior ST elevation when ablating CTI resolved by intravenous nitroglycerine and one transient AV block requiring temporary pacing for > 24 h. CONCLUSIONS: FPFA was a highly versatile method to treat atrial arrhythmias with high first-pass efficiency. UHDx revealed acute homogenous low-voltage lesions in ablated areas. More data is needed to establish lesion durability and limitations of FPFA.
27
Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial
Atul Verma, David E. Haines, Lucas V.A. Boersma et al. · Circulation · 2023 · 549 citations · Full text
Pulsed Field Ablation of Paroxysmal Atrial Fibrillation
Vivek Y. Reddy, Srinivas R. Dukkipati, Petr Neužil et al. · JACC. Clinical electrophysiology · 2021 · 523 citations · Full text
Pulsed Field Ablation in Patients With Persistent Atrial Fibrillation
Vivek Y. Reddy, Ante Anić, Jacob S. Koruth et al. · Journal of the American College of Cardiology · 2020 · 389 citations · Full text
Medicine, Cardiology, Surgery +15