Frontiers in Bioengineering and Biotechnology · 2023 · 26 citations · 43 references
EngineeringBioengineeringMolecular BiologyAnalytical ChemistryBiosensorsSensorsAptamer-based BiosensorsClinical BiosensingElectrochemical BiosensorsElectrochemical DetectionNanomaterial-based BiosensorsNanosensorsAssayBiomarkersBiosensor DevelopmentCancer Biomarker DetectionDisposable ElectrodesElectrochemical AptasensorsElectrochemical BiosensingGold Nanoparticle Biosensors
The quantification of alpha-fetoprotein (AFP) as a potential liver cancer biomarker which is generally found in ultratrace level is of significance in biomedical diagnostics. Therefore, it is challenging to find a strategy to fabricate a highly sensitive electrochemical device towards AFP detection through electrode modification for signal generation and amplification. This work shows the construction of a simple, reliable, highly sensitive, and label-free aptasensor based on polyethyleneimine-coated gold nanoparticles (PEI-AuNPs). A disposable ItalSens screen-printed electrode (SPE) is employed for fabricating the sensor by successive modifying with PEI-AuNPs, aptamer, bovine serum albumin (BSA), and toluidine blue (TB), respectively. The AFP assay is easily performed when the electrode is inserted into a small Sensit/Smart potentiostat connected to a smartphone. The readout signal of the aptasensor derives from the electrochemical response of TB intercalating into the aptamer-modified electrode after binding with the target. The decrease in current response of the proposed sensor is proportional to the AFP concentration due to the restriction of the electron transfer pathway of TB by a number of insulating AFP/aptamer complexes on the electrode surface. PEI-AuNPs improve SPE’s reactivity and provide a large surface area for aptamer immobilization whereas aptamer provides selectivity to the target AFP. Consequently, this electrochemical biosensor is highly sensitive and selective for AFP analysis. The developed assay reveals a linear range of detection from 10 to 50000 pg mL −1 with R 2 = 0.9977 and provided a limit of detection (LOD) of 9.5 pg mL −1 in human serum. With its simplicity and robustness, it is anticipated that this electrochemical-based aptasensor will be a benefit for the clinical diagnosis of liver cancer and further developed for other biomarkers analysis.
43
Nanoparticles: Properties, applications and toxicities
Ibrahim Khan, Ibrahim Khan, Khalid Saeed et al. · Arabian Journal of Chemistry · 2017 · 6.8K citations · Full text
Pattarachaya Preechakasedkit, Weena Siangproh, Nanthika Khongchareonporn et al. · Biosensors and Bioelectronics · 2017 · 185 citations
Hua‐Ping Peng, Yan Hu, Pan Liu et al. · Sensors and Actuators B Chemical · 2014 · 155 citations