Journal of Water Pollution Control Federation · 1990 · 18 citations · 10 references
EngineeringChemical EngineeringEnvironmental EngineeringBioreactor DesignWastewater TreatmentWater TreatmentActivated Sludge ProcessBiological Treatment ProcessesSludge HandlingSludge ManagementSludge TreatmentWastewater ManagementAerobic TreatmentBulking SludgeLong-term Operating PerformanceSludge BulkingWastewater AerationWastewater Sludge ManagementWastewater Treatment PlantsWastewater Treatment Processes
The effect of installing selectors to control filamentous bulking at four full-scale nitrifying wastewater treatment plants was eval uated. The results indicate that a selector can be effective in controlling filamentous sludge bulking. Little difference in effectiveness was observed for aerobic, anaerobic, or anoxic selectors. Long-term operating data indicate that selectors, coupled with an appropriate aeration basin con figuration, are capable of producing a nonbulking activated sludge (SVI less than 150 mL/g). Average S Vis in the 60 to 90 mL/g range can be expected, with values as low as 20 to 30 mL/g observed on occasion. An aerobic selector was not effective in controlling bulking in a complete mix nitrifying system using surface mechanical aerators. Res. J. Water Pollut. Control Fed., 62, 676 (1990).
10